Ventilation 

This  terminal  must 

NOT

  be  operated  in  an  environment  with  restricted 

ventilation. There must be at least 25 mm air clearance around any top or side 
ventilation  holes  with a free flow of air around the  unit at 

ALL

 times for the 

installation. 
 

Operating Environment 

The equipment must not site in direct sunshine, near a heater or in a damp and 
must be free from contaminants like dust, smoke or fume. 
The equipment must not be operated or stored in extremes of both temperature 
and humidity/moisture. 
(Operating  range  0

°

C

 

to  +  40

°

C  and  up  to  80%  relative  humidity  –  non 

condensing max. wet bulb 26

°

C) 

 

Power Supply 

 
The  power  cable,  the  power  outlet  and  any  power  fusing  arrangements  must 
conform to local safety regulations. 
 

UPS Battery (option) 

General care: 

The  UPS  battery  is  consumable  beyond  product  warranty.  Please 

definitely observe the alerts in beginning of this manual. If the equipment is to 
be powered off for more than few days, please always 

disconnect

 the battery 

from  the  system.  Reconnect  it  and  turn  on  the  system  to  recharge  the  battery 
for 1 ~ 2 hours every 3 months for temperature lower than 30

°

C. Recharge for 

1 ~ 2 hours every month for temperature over 30

°

C. Temperature above 

40°C 

must  be  strictly  avoided

  as  it  could  cause  termination  of  battery  life  and 

unexpected  result  even  if  the  battery  is  not  in  work.  The  UPS  battery  can 
support  basically  the  data  preservation  and  smooth  running  of  the  system 
during  intermittent  or  few  minutes

 

(2  ~  6  min.  depending  on  loading  and 

battery condition) power failure if the UPS function module option is installed.

 

Battery replacement: 

In  the  preloaded  OS  for  a  HT/PB-3600  series  with  UPS  function 

module  option,  there  is  a  built  in  utility  Posiflex 
Power  Switch  Manager  that  will  indicate  the  UPS 
battery

 

status of the battery. When an installed UPS 

battery  is  found  to  be  disabled  or  when  pop  up 
warning  message  like  this  picture  appears,  please 

Summary of Contents for HT-3600 Series

Page 1: ...n loss of data or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technology Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains on...

Page 2: ...erminals It does not explain any application software that may be supplied with it We intend to provide our customers with all technology advantages available by evolving the product design to incorporate appropriate changes and improvements So some detail differences may exist between this manual and the equipment supplied For more detailed or technical information please refer to the CD ROM disc...

Page 3: ...rking One LAN port Ethernet 10 100 1000 Base T with LAN status indicators on jack Serial Ports There are 4 serial ports in a HT PB 3600 system with optional 5V through BIOS setting and 12V by jumper setting power on COM1 2 3 4 and it is default as no power at delivery Parallel Port Each HT PB 3600 system is equipped with a parallel port that supports SPP EPP ECP VGA Port There is a VGA connector f...

Page 4: ...r must be upgrade to 150W i SD 300 for HT 3600 SYSTEM BOX CONTENTS When you receive the system box you will find it contains several items HT 3600 system unit with the 12 1 LCD panel integrated on top or PB 3600 system unit without the cashier display panel User s manual Recovery DVD for preloaded OS or Posiflex Product Information DVD for driver utilities without OS Optional components installed ...

Page 5: ...m unit before pressing these 2 springs The LCD and touch panel may flip forward by gravity and get or cause damage by hitting anything in front of the system unit For the PB 3600 system the maintenance technician must always pay attention to always disconnect all power and cable connections before pressing the 2 springs and not to cause any damage either in the top cover opening operation after pr...

Page 6: ...o add a PCI extension card However the whole operation will involve cautiously accessing the interior of the system replacing the slot window metal plate applying the card LCD DISPLAY for HT 3600 only Push down the round plastic button at rear of the display base as circled in right picture to adjust the display up and down Release the button when done will lock the panel firmly for application Pu...

Page 7: ...ons the connection to the HT 3600 system is one USB cable inserted to the extended USB port at top right edge of the system unit as circled in the upper picture at right After removing the plastic cover by pushing it side way the extended USB port can be found as marked in the lower picture at right The USB cable from the optional side mount upgrade kit SD 300 should be inserted in the cable hook ...

Page 8: ...er drivers in OS recovered HDD and the latest versions of these required drivers will be available on our web http www posiflex com or http www posiflex com tw Now please follow instructions from your system integrator for software recovery after OS recovery and driver installation OPERATING SYSTEM INSTALLATION This product is highly professionalized equipment The installation of an OS into a mach...

Page 9: ...rve the alerts in beginning of this manual If the equipment is to be powered off for more than few days please always disconnect the battery from the system Reconnect it and turn on the system to recharge the battery for 1 2 hours every 3 months for temperature lower than 30 C Recharge for 1 2 hours every month for temperature over 30 C Temperature above 40 C must be strictly avoided as it could c...

Page 10: ...ay cause permanent damage to any other monitor not designed to use this facility Please use only a Posiflex LM 2010 monitor designed for the HT system Consult your dealer if you have any doubt It is strongly advised that connection disconnection to this port should never take place when system power is ON The video memory shares from the system memory The video memory size shares system memory 128...

Page 11: ...n Control The system may also turn on according to some preset conditions such as Modem Ring Up and LAN Wake Up To utilize Modem Ring Up function please enter the CMOS setup by pressing F2 key at system boot up choose for Other Control in Power and make the Resume on Modem Ring ON for Modem Ring Up Save the configuration and exit the CMOS setup program The Preset Power on Control will then be read...

Page 12: ...loaded OS is ordered the required driver will be already installed in the preloaded OS However the driver will always be available over our web site http www posiflex com Touch Function Mouse emulation The touch panel in HT 3600 system works like a standard mouse within the primary screen display area when its driver is properly installed However if the system is running under safe mode due to a p...

Page 13: ...in a right button mouse click at the point touched After touching the left button in this drawing the screen touch will resume the left button function This program also controls the beep generated when the touch panel is touched the detail in right button click emulation and also provides touch panel re calibration In principal the touch panel requires no further calibration once properly set USB...

Page 14: ...ull the front cover out from this opening to release the left side hook of front cover from the chassis as indicated by the hollow arrow in the right picture Please then pull the bottom side of front cover forward to release the bottom hooks of front cover from the chassis as indicated by hollow arrow in left picture Now pull the left side of front cover down a little to free it from the main cove...

Page 15: ...ul attentions must be taken throughout the further cleaning operations below When the main unit is opened there must be no liquid spill no electro conductive material no electric charged device come into the area of the main unit Please also note that not to touch any component or cable inside Please first disconnect every cable from the main unit and for the HT 3600 turn the LCD panel to straight...

Page 16: ...ove any dust or threads accumulation away from outsides of both ventilation grids on chassis exposed after removal of the front cover as in pictures below and close back the top cover when done 警告使用者 警告使用者 警告使用者 警告使用者 這是甲類的資訊產品 在居住的環 境中使用時 可能會造成射頻干 擾 在這種情況下 使用者會被要 求採取某些適當的對策 T31454 Side Ventilation Grids on Chassis ...

Reviews: