ready after a normal power off.  For LAN wakeup, an operating caller system 
connected through LAN to the system is required. It also requires a qualified 
networking technician to check the LAN chip ID of the  HT  system for the 
caller system to wake it up. 

When the HT system is turned off after a successful boot up, the 

preset automatic power on functions will keep monitoring for the preset 
conditions and turn on the system when the preset conditions are met. 

Please note that if the HT system is improperly turned off before a 

complete boot up procedure, the above preset power on control functions will 
be disabled until next turning off after a complete boot up. 

Emergency Power Off 

In case of serious system halt due to any reason, the system could fail 

to be powered off through normal means. Press and hold the Power ON/OFF 
Switch for Emergency Power Off. Release the switch after the system powered 
off. It will take about 4 seconds if no UPS function module installed and it 
takes about 10 seconds if the option installed. If there appears to give a special 
coded beep tone in the pattern “short, long, short, long, short” prior to the 
system power off in this process, please remove the AC power and wait for 
few minutes to allow the hardware registers to reset (If there is no such beep, 
AC removal is not required). Then you may restart the system and take 
remedial action against the precious failure. 

MAIN LCD TOUCH MONITOR

 

Mechanical Adjustments 

The 12.1” LCD color display is integrated on display platform to give 

the operator the clearest view. The display may be adjusted to have the 
inclined angle from 42.5° to 77.5° and rotated from straight forward to 16° to 
the left. 

Display Controls 

On lower left edge of back of the LCD panel 

there is a plastic wheel knob as circled in the picture at 
right. Turning this knob up or down changes the 
brightness of screen display accordingly. 

Display Utility Driver 

The end user of the HT terminals is not supposed to install the utility 

drivers personally. If an optional preloaded OS is ordered, the required driver 
will be already installed in the preloaded OS. However, the driver will always 
be available over our web site: http://www.posiflex.com 

 
 

Summary of Contents for HT-4000 Series

Page 1: ...uding without limitation loss of data or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual...

Page 2: ...hole system till completely exhausted Repeatedly using it up or improper maintenance reduces the battery life dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you...

Page 3: ... This Open Standard Architecture ensures that this terminal can use the PC application software and development tools that are now inexpensively available and abundant The terminal is powered by most up to date CPU and provides a color TFT LCD screen with a resistive type touch control panel on sturdy and easily adjustable structure on top of the main unit It may be used as a self content unit or ...

Page 4: ...automatically upon an incoming COM port Modem call or LAN status or data packet received on LAN or a preset time day week month THE OPTIONAL ITEMS Note Underlined items below must be installed prior to delivery from factory Attempt to apply them by end users is either too difficult or is likely to cause damages Italic items below are stand alone peripheral devices a DRAM Memory Expansion Upgrade u...

Page 5: ...Most recommended KB 6000 KB 6200 series or KB 6600 n Bar Code Scanner Short range type near contact and long range type 250 mm for CD 3830 CCD scanners o POS printer Posiflex 9 pin dot matrix impact printer or Posiflex thermal printer of RS232 serial interface parallel interface USB interface or even wireless interface SYSTEM BOX CONTENTS When you receive the system box you will find it contains s...

Page 6: ... installed in the system delivered Therefore no more installation is required However please note that when the powered USB ports option is installed adding a half length PCI extension card will no longer be possible HALF LENGTH PCI EXTENSION CARD If the HT system is not installed with the powered USB ports option adding a half length PCI extension card is possible However the whole operation will...

Page 7: ...ton at delivery Please take it out and place it in the battery compartment at center upper part of the connection area indicated as upper rectangle in picture above Connect the cable to its connector in the main connection area beneath the battery compartment only when the system is about to power up for operation Always disconnect the UPS battery when the system is to be left powered off for more...

Page 8: ...edge of the system unit as circled in the upper picture at right After removing the plastic cover by pushing it side way the extended USB port can be found as marked in the lower picture at right AUDIO PORT The audio output port must be connected either the earphone or a pair of speakers with booster or amplifier if used PROGRAMMABLE KEYBOARD OPTION All types of Posiflex programmable keyboards can...

Page 9: ...siflex CR 3100 or CR 3200 or CR 4000 or CR 4100 or CR 4210 be used for best compliance The HT system will directly control the cash drawer using the cash drawer port CR both to operate the opening mechanism and to monitor the drawer open status Both functions may be accomplished under software control of the COM1 serial port Use the cable supplied with the CR 3X00 4X00 cash drawer Part No CCBLA 18...

Page 10: ...below for operating system recovery only if your system integrator does not advise otherwise For the HT system preloaded with Windows system on HDD Posiflex provides recovery CD delivered with the hybrid terminal for the preloaded operating system The System Integrator shall take care of software restoration after OS recovered Use a Posiflex supplied USB interface external CDROM drive for such act...

Page 11: ...Part 11 system without preloaded OS is highly discouraged Posiflex shall not be responsible for any technical support to questions arisen due to non preloaded OS ...

Page 12: ... local safety regulations UPS Battery option General care The UPS battery is consumable beyond product warranty Please definitely observe the alerts in beginning of this manual If the equipment is to be powered off for more than few days please always disconnect the battery from the system Reconnect it and turn on the system to recharge the battery for 1 2 hours every 3 months for temperature lowe...

Page 13: ...onitor not designed to use this facility Please use only a Posiflex monitor designed for the HT system Consult your dealer if you have any doubt Note 12 volt DC power is available on pin 9 of the VGA connector and is supported by the UPS function if the UPS function module option is installed The video memory of this port shares from the system memory The video memory size can be set in the BIOS C...

Page 14: ...normal supply of the AC power Hardware Power Switch This button is located at bottom front corner of right side as in right picture and can be used to turn the system on and off alternatively if no optional UPS function module installed When this option is installed this hardware switch can also be programmed to be an ON only switch through software command so that when this switch is accidentally...

Page 15: ...ut 10 seconds if the option installed If there appears to give a special coded beep tone in the pattern short long short long short prior to the system power off in this process please remove the AC power and wait for few minutes to allow the hardware registers to reset If there is no such beep AC removal is not required Then you may restart the system and take remedial action against the precious...

Page 16: ...pe touch control panel one must be aware that if you connect any monitor to the VGA port of HT system for extended secondary display application you can not apply any touch control function for this secondary display due to driver conflict concerns The operation range of a PS 2 mouse is also limited within the primary display area A program named Posiflex Touch Terminal Manager is installed in the...

Page 17: ... and regulating each required fan power to gain maximum ventilation effect with lowest possible noise This function is disabled by default at delivery The user can decide to engage this function by clicking Start Programs Posiflex Tools Posiflex Fan Control to pop up a window like the right picture Click Enable then Apply to engage this function in background This function will remain operating ev...

Page 18: ...s cover the 5 V DC and 12 V DC supply in all 4 COM ports and UPS status sense Please note that only those qualified technicians may adjust in the service window with information from Posiflex and the contents in the service window may change without notice as time develops Please visit our web http www posiflex com or consult your dealer for technical support on setup of these jumpers Please defin...

Page 19: ... the customer display also called a pole display when an option of customer display is purchased with the PST system Accessories Carton This contains most of the small parts and loose items for PST7700 and PST7705 as follows l COM1 terminator 1 piece l 1 set of keys 4 pieces for keyboard key switch l 1 set of keys 2 pieces for front door lock l Keyboard type dependent accessories as listed below l...

Page 20: ...Part 20 警告使用者 這是甲類的資訊產品 在居住的環 境 中 使 用 時 可 能 會 造 成 射 頻 干 擾 在這種情況下 使用者會被要 求採取某些適當的對策 T31454 ...

Reviews: