HT-4600/PB-4600 series Technical Manual 47
+12 V DC SUPPLY SELECT FOR COM5/6
(Note)
JP2 STATUS
COM5/6 PIN1 SETTING
1 – 3 short
COM5 Pin1 connected to 12 V
3 - 5 short
COM5 Pin1 connected as DCD
2 – 4 short
COM6 Pin1 connected to 12 V
4 - 6 short
COM6 Pin1 connected as DCD
Note:
Please note that the 5 V or 12 V DC supply should be selected only for
supporting the Posiflex serial devices that are designed to be powered from this source.
Whenever such Posiflex device is to be removed from this port, the 5 V or 12 V DC
supply must be deselected.
LCD / TOUCH CONTROL CARD
COMPONENT SIDE
HT-44 (PS/2 & USB touch interface)
JP1
Touch1
LVDS1
BZ1
CN2
D10
D11
JP1