Part 14
USING THE TOUCH POS
APPLICATION ENVIRONMENT
It is
very
important that you check the following operational
guidelines:
Ventilation
This terminal must
NOT
be operated in an environment with
restricted ventilation. The installation should be such that there is at least
25mm air clearance around any top or side ventilation holes. The installation
must also be such that there is a free flow of air around the unit at
ALL
times.
Operating Environment
The equipment must not be operated or stored in extremes of both
temperature and humidity/moisture. (Operating range 5°C to 40°C and up to
80% humidity – non condensing)
UPS Battery (option)
General care:
The UPS battery is consumables beyond product warranty. Please
definitely observe the alerts in beginning of this manual. If the equipment is to
be powered off for more than few days, please always
disconnect
the battery
from the system. Reconnect it and turn on the system to recharge the battery
for 1 ~ 2 hours every 3 months for temperature lower than 30
°
C. Recharge for
1 ~ 2 hours every month for temperature over 30
°
C. Temperature above
40°C
must be strictly avoided
as it could cause termination of battery life and
unexpected result even if the battery is not in work. The UPS battery can
support basically the data preservation and smooth running of the system
during intermittent or few minutes (3 ~ 8 min. for TP/LT-5600/5700/5800 or 2
~ 6 min. for TP/LT-8000 depending on loading and battery condition) power
failure.
Battery replacement:
In the preloaded OS for a Jiva system, there is a built in utility Power
Manager that will interface the UPS battery monitor status with user. When
battery monitor disables the battery charging as designed while the UPS
function of the system is originally enabled, in other words the UPS battery is
found out of order if actually installed, there will be a popup message as the
picture at right asking the user to agree disabling the
UPS function. The system will operate under
deactivated UPS function no matter agreed or not.
However, the monitoring goes on and the popup
message will come back on next system power up boot if not agreed. In any
case, please replace the used up UPS battery at power off if the battery is well