USING THE TOUCH TERMINAL 

APPLICATION ENVIRONMENT 

It is 

very

 important that you check the following operational 

guidelines: 

Ventilation 

This terminal must 

NOT

  be operated in an environment with 

restricted ventilation. There must be at least 25 mm air clearance around any 
top or side ventilation holes with a free flow of air around the unit at 

ALL

 

times for the installation. 

Operating Environment 

The equipment must not be operated or stored in extremes of both 

temperature and humidity/moisture. (Operating range 5°C to 40°C and up to 
80% humidity – non condensing, max. wet bulb 26

°

C) 

UPS Battery (option) 

General care: 

The UPS battery is consumables beyond product warranty. Please 

definitely observe the alerts in beginning of this manual. If the equipment is to 

be powered off for more than few days, please always 

disconnect

 the battery 

from the system. Reconnect it and turn on the system to recharge the battery 
for 1 ~ 2 hours every 3 months for temperature lower than 30

°

C. Recharge for 

1 ~ 2 hours every month for temperature over 30

°

C. Temperature above 

40°C 

must be strictly avoided

 as it could cause termination of battery life and 

unexpected result even if the battery is not in work. The UPS battery can 
support basically the data preservation and smooth running of the system 
during intermittent or few  minutes  (15 ~ 30 min. depending on loading and 
battery condition) power failure. 

Battery replacement: 

In the preloaded OS in HDD for a KS system, there is a built in utility 

Power Manager that will  interface the UPS battery  monitor status with user. 
When battery monitor disables the battery charging as designed while the UPS 
function of the system is originally enabled, in other words the UPS battery is 
found out of order if actually installed, there will be a popup message as the 
picture at right asking the user to agree disabling the 
UPS function. The system will operate under 

deactivated UPS function no matter agreed or not. 
However, the monitoring goes on and the popup 
message will come back on next system power up boot if not agreed. In any 
case, please replace the used up UPS battery at power off if the battery is well 
connected there but found inoperable by such messages. 

Summary of Contents for KS - 6215N

Page 1: ...esulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technologies Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware con...

Page 2: ...improper maintenance reduces the battery life dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you are going to re power on the system Replace the battery as soon...

Page 3: ...NTRODUCTION PRODUCT PICTURES Front Views Side Views 1 1 11 12 Slim base Universal Base 10 10 9 9 6 5 Slim base 13 14 15 6 1 Slim base 6 3 4 1 1 Universal Base Slim base Universal Base 4 5 6 8 7 7 8 9 9 6 5 2 2 ...

Page 4: ... Removal hollow in cable cover 9 Lock release lever for tilt angle adjust 10 Lock release button for main unit detach 11 Touch open cover 12 Power switch 13 Brightness adjust thumb wheel 14 Touch open door latch 15 PS 2 KB port 16 Rear connect cover 17 Power connector hole 18 Cable exit 19 2nd Cable exit 18 Universal Base 21 Slim base 18 19 20 21 1 1 Slim base Universal Base 7 7 6 5 18 18 16 16 17...

Page 5: ...port WinCE Win XP Pro WEPOS POS Ready and Linux environment f High quality 15 TFT active matrix LCD panel g Brightness control by either software or hardware h Vertical type LCD panel with easy tilt angle adjustment from 15 to 70 i Durable resistive type leading edge Infra Red type optional touch panel that endures 35 million touches min at same spot j Spill proof water resistant structure allowin...

Page 6: ...t MODEM ring or LAN Option Items Note The underlined items in the following list means that option must be set prior to shipment from the factory The rest items can be set by the dealers a DDR2 SDRAM memory expansion up to 1GB b RS232 interface Infra Red type touch panel durable for 50 million touches min at same spot c 2 HDD installation or uDOC d Integrated side mount upgrade kit SD400 MSR finge...

Page 7: ...ible then Please first note orientations of every existing cable connection and then disconnect every cable properly before separating the main unit from the adjustable stand assembly Please note that the click lock spring has to be pressed down prior to pulling out the connector such as the LAN port Please also note that the fixing screws have to be loosened free prior to disconnection such as th...

Page 8: ...om plate up and the inside of an example slim base model looks like this in the above right picture The inside of an example universal base model will look like the picture on next page Both with numbered items listed on next page However there could be some variation to the contents inside depending on what option items actually installed Step A Prepare a soft clean flat surface such as a piece o...

Page 9: ...through the 2 standing slits on base box to fix the battery in position firmly Route the battery connection cable through appropriate passage to the battery connector on the main unit Please remove the UPS battery bracket fixing screw and slide right the UPS battery bracket to take it out for universal base model as in left picture Put the battery in at the other end first and remount the bracket ...

Page 10: ...or illustration purpose only Please push the plastic hook plate with finger through the top opening in the stand assembly to remove the rear connect cover 12 2nd LCD Panel Or Customer Display Fit the joint base of PD 2501 or PD 2602 or LM 6101 to the rear connect cover opening Please route the interface cable through the normal cable exit under the joint base as in the 2 pictures Fit 2 screws thro...

Page 11: ...ort and COM port power supply function Please consult your dealer for technical support on setup of these jumpers Please note that only those qualified technicians may adjust in the service window with information from Posiflex and the contents in the service window may change without notice as time develops SIDE MOUNT UPGRADE KIT Remove the 2 circled screws in last picture above to remove the cov...

Page 12: ...ed type touch panel is used KS 6115U 294 5 391 5 WALL MOUNTING The wall mount model is delivered without any base but with a wall mount kit Please follow the installation guide that comes with the wall mount bracket to fix the wall mount bracket on wall and then hang the main unit with the matching pegs into the matching holes on wall mount bracket Please note that since there is no base for the w...

Page 13: ... care of software restoration after OS recovered A Posiflex supplied USB interface CDROM drive will be required for such action Other brand CDROM drive may require its specific driver different from what supported in the recovery CD Should there be any difficulty in using the Posiflex supplied USB interface CDROM drive in recovery please try disable the USB 2 0 function of system BIOS setup by goi...

Page 14: ...Part 14 Inc shall not be responsible for any technical support to questions arisen due to non preloaded OS ...

Page 15: ... hours every month for temperature over 30 C Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work The UPS battery can support basically the data preservation and smooth running of the system during intermittent or few minutes 15 30 min depending on loading and battery condition power failure Battery r...

Page 16: ... power outlet and any power fusing arrangements must conform to local safety regulations Please never do any connection disconnection when system is still powered on Please always keep the external power adaptor in a free air circulation POWER ON OFF Touch Open Cover A gentle tap on the touch open cover at left side of the main unit will open the cover and show the power switch thumb wheel knob fo...

Page 17: ...re registers may be confused causing trouble for system restart or even this forced power off please disconnect the UPS battery if installed and the AC power supply for few minutes This may allow all hardware registers to reset This switch can also be programmed as an ON only switch That means if the application program issues a command compliant with the KS series technical manual this switch wil...

Page 18: ...et Please note that if the KS system is improperly turned off before a complete boot up procedure the above preset power on control functions will be disabled until next turning off after a complete boot up DISPLAY ISSUES Main LCD Display For best viewing result please set your display resolution at 1024 x 768 with 16 2 M colors In configuration of system memory max 64 MB can be shared as the vide...

Page 19: ...rner of the main unit but no direct access port in the main unit The external access to audio ports can be found in the side mount option kit like SD 400 with a Microphone in and a stereo line out jacks at its bottom surface as circled in the right picture The internal speaker will be automatically disconnected when a plug is inserted in the line output jack HDD SATA PORTS The 2 5 HDD if installed...

Page 20: ...f the mouse To obtain the effect like clicking on the right button of a mouse touching any point on the screen surface after touching the right click sticky button results as a click on the right button of the mouse at that point Posiflex USB Touch Manager A program named Posiflex USB Touch Manager and a right click sticky button tool in the program group Posiflex USB Touch Tools is installed in t...

Reviews: