background image

 

 

Part 7 

INSTALLATION GUIDES

CAUTION: Before any installation or cable connection to the set, please 

always make certain that the system is turned off and the 
external power source to the set is removed to prevent electric 
hazard! Never touch any metal pin in the connectors or 
circuits to avoid high voltage hazard or electrostatic discharge 
damage unless the operator is well grounded. Failure to do the 
above will void the product warranty! 

TECHNICAL MANEUVERS

Some technical maneuvers in KS-6815 series such as serial COM port 

+5V power supply settings and VGA port +12V power supply setting are 
supported in system BIOS setting. However, such support is limited to the 
application of specific Posiflex peripherals and must be disabled when the 
Posiflex peripherals are disconnected. 

Failure to follow the discipline would 

result in electric or fire hazard and such consequences are not covered by 
product warranty!

 To manipulate each of these functions please select 

“Integrated Peripherals” in system BIOS setup and enter “SB GPIO Control”. 

The rest applicable technical maneuvers include system CMOS data 

reset, system reset, DRAM upgrades, physical access to CF memory card if the 
CF card reader option is installed and installation of optional SATA HDD in 
base, optional RAID function reset. All these technical maneuver operations 
require purchase of applicable Technical Manual from Posiflex or consultation 
from Posiflex authorized dealers and should be handled only by a 

qualified 

technician

OPENING CABLE COVER

Please follow steps A to C sequentially with reference to pictures 

below to remove the cable cover for both slim and universal base models. 

Step A:

 Push lock/release lever for tilt angle adjust 

backward 

Step B:

 Turn panel backward to most horizontal position 

Step C:

 Pull at the removal hollow 

toward the user 
 
 
 

Tips:

  If there is trouble removing 

the cable cover, try pressing 
the arrowed portion of cable cover in the rear 
view picture at right at the same time. 

C

 

A

 

B

 

Summary of Contents for KS - 6815

Page 1: ...ts resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technologies Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware...

Page 2: ...ife dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you are going to re power on the system Replace the battery as soon as the monitoring software indicates the ...

Page 3: ... PRODUCT PICTURES Front Views Side Views 5 3 1 With side mount kit 4 Panel tilted back 6 7 8 4 5 1 Right side view 9 8 4 13 1 15 4 Left side view Inside touch open door 12 14 16 17 2 3 1 Panel tilted straight 4 11 5 10 5 ...

Page 4: ...501 or PD 2602 11 Optional rear top mount kit PD 310 or PD 2604 12 Touch open cover 13 Power switch 14 Brightness up button 15 Touch open door latch 16 Brightness down button 17 USB ports in touch open door 18 Kensington security slot 19 Rear connect cover 20 Cable exit 21 Bottom plate 22 Base mount device cable groove 23 Cable holder 24 Cable passage in bottom plate 25 Rubber foot with bottom pla...

Page 5: ...type optional j Spill proof water resistant structure allowing easy cleaning k Easy maintenance construction l Various I O ports supported including 1 3 serial ports with 2 in form of DB9 connectors and 1 in form of 10 pin RJ45 type modular connector The 2 DB9 connectors are supported with capability for 5V DC support through BIOS setup 2 6 standard USB ports with 2 at side and 4 in I O area below...

Page 6: ...et by the dealers a DDR2 SODIMM memory expansion up to 2GB max b RS232 interface Infra Red type touch panel durable for 50 million touches min at same spot c CF card reader kit or SSD kit It can t coexist with HDD in main unit d Base installed SATA HDD e RAID 1 control for both SATA HDD s in main unit and in base f Integrated side mount upgrade kit SD400Z with options MSR optical fingerprint senso...

Page 7: ...overed by product warranty To manipulate each of these functions please select Integrated Peripherals in system BIOS setup and enter SB GPIO Control The rest applicable technical maneuvers include system CMOS data reset system reset DRAM upgrades physical access to CF memorycard if the CF card reader option is installed and installation of optional SATA HDD in base optional RAID function reset All...

Page 8: ...warranty SEPARATING MAIN UNIT In order to settle the touch terminal properly in a point of sale system all the cable connections have to be routed through its base either slim or universal Therefore please observe the procedures from A to C below to separate the main unit from the slim base stand assembly after all cables in cable cover disconnected Step A Prepare a soft clean flat surface such as...

Page 9: ...particular attention to the environment requirement for UPS battery in next chapter USING THE TOUCH TERMINAL CABLE PASSAGE FROM BOTTOM Please route all cables through the cable passage to main unit in desktop mount application Hold them together with a cable tie Pass all cables other than those for optional HDD kit in base or optional UPS battery through the cable exit to external connections BASE...

Page 10: ...ort Fit the interface cable into the base mount device cable groove under bottom plate ROUTING THE CABLES THROUGH BASE Place all the cables required for connections to the main unit except those for the integrated attachment through the front part inside the base stand assembly Be sure not to damage any cable during this operation Now turn the adjustable base stand assembly back to normal orientat...

Page 11: ...crews in last picture above to remove the cover for side mount upgrade kit Take out the cable inside this cover as circled in right picture and connect it to connector inside the side mount upgrade kit like SD400Z as arrowed in same picture Gently arrange the excessive length of this cable back in the hole and screw fit it back to the position originally occupied by the cover Please reserve the co...

Page 12: ...connection to the CR port in KS system This cable has a 6 pole plug at one end and an 8 pole plug at the other The 8 pole plug should be inserted into the connector marked signal cable from POS Printer at the rear of the cash drawer The 6 pole plug should be inserted in the connector marked CR found in the main connection area in the system The user may also purchase the optional 2 in 1 cash drawe...

Page 13: ...e that all the cables come out of the stand from the lower edge and won t get trapped by this mounting operation If later on you want to remove the main unit from the stand you ll have to press down the lock release button on back of the stand at the time lifting the main unit For desk top counter application the total dimension of KS 6815 occupies a space of 378 mm wide 313 to 316 mm deep and 268...

Page 14: ...only Using it otherwise may wipe out whatever stored in the HDD All upgrade devices drivers needed for manual installation in usual way are available in the subfolder drivers in OS recovered HDD and the latest versions of these required drivers will be available on our web http www posiflex com tw Then follow instructions from your system integrator for software recovery OPERATING SYSTEM INSTALLAT...

Page 15: ... 3 months for temperature lower than 30 C Recharge for 1 2 hours every month for temperature over 30 C Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work The UPS battery can support basically the data preservation and smooth running of the system during intermittent or few minutes 30 min up dependin...

Page 16: ...al power adaptor in a free air circulation POWER ON OFF Touch Open Cover A gentle tap on the touch open cover at left side of the main unit will open the cover and show the power switch at top area It is preferable to keep this door closed through daily operation There must always be at least 10 seconds waiting before switching on again once the system is powered off successfully Power Indicator T...

Page 17: ... has the ability to power off the machine In preloaded Windows Posiflex Power Switch Manager in Posiflex Tools in the Program Files helps managing these functions Software Support Features The KS series provides a software power off command for application program maneuvers The KS also provides a specific means for the software to detect if the system is working on external or UPS battery power Du...

Page 18: ... LCD brightness adjust buttons 4 in I O area All of them comply to USB 2 0 standard DISPLAY ISSUES Main LCD Display For best viewing result please set your display resolution at 1024 x 768 with high color The system Video Memory is shared from system memory The video memory size is default 8 MB and can support DVMT up to 224 MB VGA Port The VGA port in the KS 6815 system supports either a base mou...

Page 19: ...ndicates the status of the primary HDD the one in main unit and the upper LED marked HDD1 indicates the secondary HDD the one in base When there is no RAID function the lower LED HDD0 indicates status of either HDD and the upper LED HDD1 indicates the status of optional CF card PARALLEL PORT In KS 6815 system the parallel port can be available only through use of the optional conversion cable It s...

Page 20: ...amed Posiflex USB Touch Manager and a right click sticky button tool in the program group Posiflex USB Touch Tools is installed in the preloaded Windows system with a USB interface touch panel controller This program can also be obtained by download from the POSIFLEX web site RS232 Touch Controller If the KS system purchased is the leading edge Infra Red type touch models the touch controller is o...

Reviews: