PST-6000 series Technical Manual 5 - 1
TM
APPLICATION GUIDES
OPERATOR DISPLAY
CRT MONITOR (FOR PST6000)
The CRT monitor used in PST6000 (VGA port built in on board) can be
considered as ordinary PC VGA monitor in application concern. However, the power
to the 9” VGA monochrome monitor is supplied through the VGA connector and is
UPS supported. Yet, when the monitor used is the 10” color monitor, the AC power is
used and is not supported by the UPS function.
LCD DISPLAY (12.1” COLOR DSTN)
As this LCD is constructed in 800 x 600 pallets, it is recommended to select
800 x 600 resolution for best vision.
CASH DRAWER
The software command to open the cash drawer or the first cash drawer with
the optional split cable CCBLA-238 is a hexadecimal code of <07> sent to COM1
port under the protocol of 9600bps, none parity, 8 data bits, 1 stop bit.
The software command to open the second cash drawer with the optional split
cable CCBLA-238 is a hexadecimal code of <17> sent to COM1 port under the same
protocol as above.
The drawer open status can be obtained through checking the communication
status of COM1 at signal RI. When there is no drawer open, the RI signal of COM1 is
always set. When there is any cash drawer opened, the RI signal of COM1 is reset.
The RI signal is obtained as the bit 6 (the second most significant bit) of the I/O
address 3Feh if the COM1 address is set to 3F8h~3FFh (conventional address for
COM1) in system configuration.
Summary of Contents for PST-6000 SERIES
Page 1: ...TM Rev A L 1 L 0 L P L 2 L 3 L 4 L 1 L 0 L P L 2 L 3 L 4 PST 6000 SERIES TECHNICAL MANUAL ...
Page 8: ...vi TM ...
Page 20: ...PST 6000 series Technical Manual 2 10 TM ...
Page 22: ...PST 6000 series Technical Manual 3 2 TM ...
Page 58: ...PST 6000 series Technical Manual 5 28 TM ...
Page 73: ...PST 6000 series Technical Manual 7 3 TM DWG 2 Unscrew the bottom ...
Page 77: ...PST 6000 series Technical Manual 7 7 TM DWG 7 Cable connections inside PST system ...
Page 82: ...PST 6000 series Technical Manual 7 12 TM ASSEMBLY DRAWING ...