GAM Quick Installation Guide 

 

 

Positron Access Solutions 

21 

Document 180-0193-001 R01 

Safety and Warnings 

To ensure your safety when servicing and installing this equipment, please take 
the following precautions: 
 
The GAM products accept 110-220Vac for powering (50-60Hz). A properly fused 
3-contact (live-neutral-protective ground) power outlet wired in accordance to the 
National Electrical Code shall be used to provide the power to the GAM unit. 
 
A  power  cord  meeting  IEC  60320  (C13  type)  is  supplied  with  the  GAM  device 
and  shall  be  used  to  bring  power  to  the  GAM.  The  primary  protective  ground 
(earthing) is provided through this cord. 
 
The  power  cord  must  always  be  disconnected  before  servicing  the  accessible 
front  panel  fuse  to  prevent  from  risk  of  electrical  shock.  Always  use  a 
replacement fuse of the proper current rating. 
 
Only qualified personnel should service this system. 
 
All wiring external to the product should follow the local wiring codes. 
 
Use of this product in a manner other than defined in this installation guide may 
cause damage to equipment or injury to personnel. 
 
If  a  problem  has  been  isolated  to  this  unit,  do  not  attempt  to  repair.  The  unit’s 
components are not user serviceable and therefore must not be replaced. Please 
return the unit to Positron Access Solutions for repair. 
 
Observe  local  practice  electrostatic  discharge  precautions  when  handling 
electronic  equipment.  Do  not  hold  electronic  plugs  by  their  edge.  Do  not  touch 
components  or  circuitry.  Use  a  grounding  wrist  strap  attached  to  a  grounding 
connection  point.  Use  only  ESD-protective  packaging  materials  when 
transporting equipment. 
 

 

 

 

 

 

 
When  installing  in  a  closed  or  multi-unit  rack  environment,  ensure  that  the 
maximum operating ambient temperature of 45°C (113°F) is not exceeded. 

Summary of Contents for GAM-12-C

Page 1: ...G hn Access Multiplexer GAM Quick Installation Guide GAM 12 M GAM 24 M GAM 12 C GAM 24 C...

Page 2: ...ositron Access Solutions 5101 Buchan Street Suite 220 Montreal Quebec Canada H4P 2R9 Telephone US and Canada 1 888 577 5254 International 1 514 345 2220 Product names other than Positron s mentioned h...

Page 3: ...2 3 G hn Ports 8 1 2 4 Local management ports 9 1 2 5 GAM LED Indicators 10 1 2 6 GAM Reset Button 11 Chapter 2 12 WEB Management 12 2 1 Introduction 13 2 2 System Management 13 2 2 1 Logging into the...

Page 4: ...7 GAM G HN RJ 45 CONNECTORS 8 FIGURE 8 CLOSE UP OF GAM G HN RJ 14 CONNECTOR 9 FIGURE 9 CLOSE UP OF GAM G HN RJ 45 CONNECTOR 9 FIGURE 10 GAM G HN F TYPE CONNECTORS 9 FIGURE 11 GAM SERIAL MANAGEMENT POR...

Page 5: ...GAM Quick Installation Guide Positron Access Solutions 5 Document 180 0193 001 R01 Chapter 1 ______________________________________ About the GAM...

Page 6: ...ithout the cost complexity and delays associated with in building fiber installation G hn is an Access technology for Operators looking to simplify their access network and backend infrastructure with...

Page 7: ...Front Plate Figure 4 GAM 24 C Front Plate 1 2 1 Power Connection The GAM devices require local 110 220Vac power and come with a country specific power cord The power connector incorporates an ON OFF p...

Page 8: ...032 o Point to point G 8031 Daisy chain another GAM Important note When connecting the SFP port to a Passive Optical Network PON fiber connection please make sure to use an Optical Network Unit ONU ap...

Page 9: ...12 C has 12 G hn F type Coax ports and the GAM 24 C has 24 G hn F type Coax ports Each F type G hn port of the GAM can serve up to sixteen 16 remote G hn end point devices using standard coax splitte...

Page 10: ...obal status and operating mode The G hn ports have status LEDs under each port The two 2 SFP ports of the GAM each have a dedicated status LED located under each SFP connector LED Condition Function S...

Page 11: ...the recessed RST button to reset the GAM When depressed for two 2 to ten 10 seconds it will perform a cold reboot of the GAM When depressed for more than ten 10 seconds it will return the GAM device t...

Page 12: ...GAM Quick Installation Guide Positron Access Solutions 12 Document 180 0193 001 R01 Chapter 2 ______________________________________ WEB Management...

Page 13: ...System Management 2 2 1 Logging into the WEB GUI The default configuration values of the GAM devices are IP Address 192 168 10 1 Subnet Mask 255 255 255 0 Username admin Password Table 2 GAM default c...

Page 14: ...the default Positron signed PKI Certificate used by the WEB GUI Administration Interface pre installed by Positron with one from your preferred Certificate Authority Note Secure HTTP is disabled by de...

Page 15: ...GAM Quick Installation Guide Positron Access Solutions 15 Document 180 0193 001 R01 Chapter 3 ______________________________________ Technical Specifications...

Page 16: ...2 Domain Master on all GAM ports MIMO or Coax Based on GigaWire Alliance specification and fully compliant with the following ITU T standards G 9960 Amendment 2 System Architecture and PHY Layer G 99...

Page 17: ...IDs Port based VLAN IEEE 802 1Q tag based VLAN IEEE 802 1ad Q in Q double tag VLAN MAC based VLAN Management VLAN Private VLAN Edge PVE Generic VLAN Registration GVRP Protocols for automatically propa...

Page 18: ...ress protocol port differentiated services code point DSCP IP precedence TCP UDP source and destination ports 802 1p priority Ethernet type Internet Control Message Protocol ICMP packets IGMP packets...

Page 19: ...RMON Embedded RMON software agent supports RMON groups 1 2 3 9 history statistics alarms and events for enhanced traffic management monitoring and analysis IPv4 and IPv6 Dual Stack Coexistence of both...

Page 20: ...GAM Quick Installation Guide Positron Access Solutions 20 Document 180 0193 001 R01 Chapter 4 ______________________________________ Safety and Warnings...

Page 21: ...eplacement fuse of the proper current rating Only qualified personnel should service this system All wiring external to the product should follow the local wiring codes Use of this product in a manner...

Page 22: ...ot achieved due to uneven mechanical loading WARNING The intra building ports Electrical Ethernet RJ 45 G hn V 24 console of the equipment are suitable for connection to intra building or unexposed wi...

Page 23: ...GAM Quick Installation Guide Positron Access Solutions 23 Document 180 0193 001 R01 Chapter 5 ______________________________________ Warranty and Customer Service...

Page 24: ...y information can be found in your Positron Access customer web portal http www positronaccess com Portal php Positron Access Solutions Sales Pricing Availability and Technical Support US and Canada 1...