GAM Quick Installation Guide
Positron Access Solutions
9
Document 180-0193-001 R01
Looking at the RJ-14 connector below, pair 1 (inner pair) is connected to pins 2
and 3. Pair 2 (outer pair) is connected to pins 1 and 4.
Figure 8:
Close-up of GAM G.hn RJ-14 Connector
Looking at the RJ-45 connector below, pair 1 (inner pair) is connected to pins 4
and 5. Pair 2 (outer pair) is connected to pins 3 and 6.
Figure 9:
Close-up of GAM G.hn RJ-45 Connector
The GAM-12-C has 12 G.hn F-type Coax ports and the GAM-24-C has 24 G.hn
F-type Coax ports. Each F-type G.hn port of the GAM can serve up to sixteen
(16) remote G.hn end-point devices using standard coax splitters (5 MHz to 2400
MHz).
Note:
coax splitters are optional and not included with the GAM devices.
Figure 10:
GAM G.hn F-type Connectors
1.2.4
Local management ports
The GAM devices have two (2) local management ports. The CRAFT port is a
standard serial (V.24, 115200, 8, N, 1)) port that provides access to the
command line interface of the GAM device. The pinout of the RJ-45 serial port is
compatible with the popular Cisco pinout as per the following diagram: