background image

 

 

 

 

Quick Start Guide 

 

Cordless Ring Scanner 9P 

 

with 

Bluetooth

®

 Wireless Technology 

 
 
 
 

 

 
 
 
 

INTRODUCTION....................................................................................... 2

 

HARDWARE PREPARATION .................................................................. 4

 

SETUP FOR WINDOWS MOBILE ............................................................ 7

 

SETUP FOR WINDOWS XP................................................................... 11

 

HARDWARE AND SOFTWARE INDICATORS ...................................... 20

 

 

2

 

I

NTRODUCTION

 

 

The Socket Cordless Ring Scanner (CRS) is a 
unique wearable device that lets you keep your 
hands free while scanning bar codes into a 

Bluetooth

 enabled Pocket PC or Windows XP 

desktop, notebook or tablet computer. 

 

The first product of its kind with a built-in 
wireless communicator, the CRS combines the 
power of laser bar code scanning with the 
convenience of 

Bluetooth

 wireless technology 

in a comfortable, hands-free solution that 
makes scanning as simple as pointing your 
finger.  

 

“Fuzzy logic” technology enables the CRS to scan even damaged, poor quality or 
hard to read bar codes. Socket’s 

Error Proof Protocol

 ensures that data is correctly 

received by the host computer.  

 

SocketScan

 keyboard emulation software directs scanned data into any Windows 

program, so you can use the CRS with your favorite application. Also included is 
Socket Connect!Agent

 software, which automatically configures and manages the 

Bluetooth

 wireless connection, requiring no interaction from the user. 

 

System Requirements 

 

Your computer should satisfy these minimum requirements: 

 

 

Any of the following operating systems:  

 

Windows Mobile 2003, 2003SE or 5.0 

 

Windows XP or XP Tablet Edition 

 

 

Any of the following 

Bluetooth

 stacks*: 

 

Socket Drakar v1.4 (from Socket SD/CF 
Connection Kits)  

 

IVT BlueSoleil version 1.6.1.4 (from 
Socket CF/USB Connection Kits) 

 

Broadcom (Widcomm) v1.4 

 

Microsoft 

Bluetooth

 stack for Windows Mobile 

 

Microsoft Windows XP Service Pack 2 

 

Toshiba 

Bluetooth

 stack 3.03.06 or greater for Windows XP 

 

 

Windows Mobile

: Software installation requires ActiveSync 4.0 or greater. 

Download it free from: 

www.socketcom.com/activesync

 

*Other stacks may be compatible but have not been tested by Socket. For Windows XP, only the 
Microsoft and IVT Bluetooth stacks are compatible with the optional Socket Connect!Agent software. 

Summary of Contents for Cordless Ring Scanner 9P

Page 1: ... support POSMicro com Monday Friday 6 AM to 5 PM Pacific Time Bulk Discounts FREE SHIPPING SE Habla Español Free ground shipping to the continental USA on orders over 100 For Help Call 1 800 241 6264 Socket CRS Quick Start Guide More information available at POSMicro com ...

Page 2: ...eyboard emulation software directs scanned data into any Windows program so you can use the CRS with your favorite application Also included is Socket Connect Agent software which automatically configures and manages the Bluetooth wireless connection requiring no interaction from the user System Requirements Your computer should satisfy these minimum requirements Any of the following operating sys...

Page 3: ...tion log in click on the Technical Support tab and click New Trouble Ticket to submit an online request for technical support Afterwards you can log in anytime to track the progress of your request If we are unable to resolve your support inquiry online we can arrange for a technical support representative to call you at a specific time 4 HARDWARE PREPARATION Charging and Installing the Battery 1 ...

Page 4: ...ecure and comfortable fit 5 Put the ring scanner on your index finger adjusting the finger strap for a secure and comfortable fit 6 Attach the wrist unit case to the wrist strap by pressing the Velcro together 6 How to put on the CRS without the wrist unit case Note After you stick the Velcro strips to the wrist unit the wrist unit will no longer fit in the case unless the Velcro strips are remove...

Page 5: ...set button 7 If desired install Connect Agent Re establish the ActiveSync connection Open the Connect Agent folder in the CD and launch the Connect AgentSetup exe file Follow the wizard to install the software 8 STEP 2 Configure Scanner Settings 1 Tap Start Settings System tab Socket Scanner Settings Alternatively tap Start Programs SocketScan Go to the Today screen Tap the SocketScan icon at the ...

Page 6: ...our mobile device connects to the CRS the SocketScan icon at the bottom of the Today screen will change into a ring icon to indicate the connection Connect Agent will save information about the CRS to automate future connections to your specific unit 10 STEP 4 Assemble and Put on the CRS Please refer to the instructions on pages 5 6 STEP 5 Scan Data into Your Application 1 Start the Windows applic...

Page 7: ...ally configures the Bluetooth settings For Windows XP Connect Agent works only with the Socket IVT and Microsoft Bluetooth stacks If you are not using Connect Agent follow the instructions for your Bluetooth stack This step is needed only the first time you connect the CRS to your PC Socket Connection Kit with IVT BlueSoleil software CF or USB 1 Turn on the Cordless Ring Scanner Press the small po...

Page 8: ...d Bluetooth Device Wizard note the COM number of the Outgoing COM port 14 Toshiba Bluetooth Stack These instructions are based on a Motion Computing tablet Refer to the manual for your Bluetooth hardware software for specific Bluetooth usage instructions 1 Turn on the Bluetooth radio of your computer Tap on the Dashboard icon on the desktop In the dashboard check Enable Internal Bluetooth Wireless...

Page 9: ...ooth software will ask you for the passkey each time you connect To stop the automatic prompts under Advanced Configuration disable the Secure Connection requirement for both the Local Service and Client Application then unpair the devices Refer to the documentation for your Bluetooth hardware software for complete instructions 16 STEP 3 Configure Scanner Settings 1 Click the SocketScan icon at th...

Page 10: ...n 2 Start SocketScan XP Click on the icon on the desktop 3 Right click the SocketScan icon at the bottom of the screen and click Connect CS If you installed Connect Agent it will automatically open the Bluetooth software and turn on the Bluetooth radio when you click Connect CS After you configure the correct Bluetooth hardware settings in SocketScan the Connect CS menu option allows you to connec...

Page 11: ...n SocketScan After the time limit for re connection attempts has passed you can click on the Socket CS Connect icon on the desktop to manually initiate re connection To end the connection click on the SocketScan icon and click Disconnect CS To turn off the CRS press the power button on the wrist unit for at least 2 seconds until you hear 2 beeps Socket Communications Inc 5 2006 Printed in U S A HA...

Reviews: