114
Motorhome - 02/11-0 - PSL-MJ11-00EN
Troubleshooting
14
14.5
Refrigerator
In the event of a defect contact the nearest customer service workshop of the
relevant appliance manufacturer. The list of addresses is enclosed with the
accompanying appliance documentation. Only authorised qualified personnel
may repair the appliance.
14.5.1
Dometic refrigerator without AES
Boiler empties, safety/
drainage valve has
opened
Temperature at the drain-
age valve below approx.
3 °C
Switch on the heater. At
temperatures below ap-
prox. 3 °C the drainage
valve opens automatical-
ly.
Battery cut-off switch or
main switch on the trans-
former/rectifier is
switched off
Switch battery cut-off
switch or main switch on
Operating voltage under
10.8 V
Charge, have charged or
renew the living area bat-
tery
Fuse is defective
Replace fuse on the
transformer/rectifier
Safety/drainage valve
does not close during
switching on
Battery cut-off switch or
main switch on the trans-
former/rectifier is
switched off
Switch battery cut-off
switch or main switch on
Operating voltage under
10.8 V
Charge/have living area
battery charged
Fuse is defective
Replace fuse on the
transformer/rectifier
Temperature at the drain-
age valve below approx.
7 °C
Switch on the heater.
When heater is not oper-
ating, drainage valve only
closes again at tempera-
tures above approx. 7 °C.
Red and green indicator
lamps are not lit
Fuse is defective
Replace fuse on the
transformer/rectifier
Fan wheel runs loudly or
unevenly
Fan wheel soiled
Contact Truma Service
Fault
Cause
Remedy
Fault
Cause
Remedy
Refrigerator does not
switch on when operating
in 230 V mode
No 230 V power supply
Connect 230 V power
supply
230 V automatic circuit
breaker has triggered
Switch on 230 V auto-
matic circuit breaker
230 V operating voltage
too low
Have the 230 V power
supply checked by a spe-
cialist workshop
Summary of Contents for D-Line 2011
Page 2: ...Motorhome 02 11 0 PSL MJ11 00EN Instruction manual ...
Page 8: ...8 Motorhome 02 11 0 PSL MJ11 00EN Records 1 ...
Page 12: ...12 Motorhome 02 11 0 PSL MJ11 00EN Introduction 2 ...
Page 18: ...18 Motorhome 02 11 0 PSL MJ11 00EN Safety 3 ...
Page 32: ...32 Motorhome 02 11 0 PSL MJ11 00EN Pitching the motorhome 6 ...
Page 98: ...98 Motorhome 02 11 0 PSL MJ11 00EN Sanitary fittings 11 ...