115
Motorhome - 02/11-0 - PSL-MJ11-00EN
Troubleshooting
14
14.5.2
Waeco refrigerator
Refrigerator does not
switch on when operating
in 12 V mode
Jumbo flat fuse (40 A) on
the starter battery is de-
fective
Replace jumbo flat fuse
(40 A) on the starter bat-
tery
Flat fuse (2 A) in the
starter battery is defec-
tive
Replace flat fuse (2 A) in
the starter battery
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
12 V operating voltage
too low
Have the 12 V power
supply checked by a spe-
cialist workshop
Refrigerator does not
switch on when operating
in gas mode
Lack of gas
Open regulator tap and
gas isolator tap
Connect a full gas bottle
Air in the gas pipe
Repeat ignition 3 or 4
times
Cobwebs or burnt resi-
due in the burning cham-
ber
Remove the ventilation
grill on the outside of the
vehicle and clean the
burning chamber
Fault
Cause
Remedy
The red LED flashes 1 to
5 times (depending on
fault) every 4 seconds
Fault in appliance
Contact customer service
Compressor running con-
stantly
Thermostat defective
Contact customer service
Compressor runs long
period
Ambient temperature is
too high
Improve ventilation
Fan defective
Contact customer service
Refrigerator does not cut
in
Fuse is defective
Replace fuse
12 V operating voltage
too low
Charging the battery
Have the 12 V power
supply checked by a spe-
cialist workshop
12 V power supply
switched off
Switch 12 V power sup-
ply on
Fault
Cause
Remedy
Summary of Contents for D-Line 2011
Page 2: ...Motorhome 02 11 0 PSL MJ11 00EN Instruction manual ...
Page 8: ...8 Motorhome 02 11 0 PSL MJ11 00EN Records 1 ...
Page 12: ...12 Motorhome 02 11 0 PSL MJ11 00EN Introduction 2 ...
Page 18: ...18 Motorhome 02 11 0 PSL MJ11 00EN Safety 3 ...
Page 32: ...32 Motorhome 02 11 0 PSL MJ11 00EN Pitching the motorhome 6 ...
Page 98: ...98 Motorhome 02 11 0 PSL MJ11 00EN Sanitary fittings 11 ...