69
Motorhome - 02/11-0 - PSL-MJ11-00EN
Electrical system
9
Remove the living area battery from the vehicle.
Install the new living area battery in the reverse order.
9.3
Transformer/rectifier (EBL 99)
Z
Do not cover the ventilation slots. Danger of overheating!
Z
Depending on the model, not all fuse slots are fitted with fuses.
Z
Further information can be obtained in the manufacturer's instruction
manual.
Fig. 72
Transformer/rectifier (EBL 99)
1
Main supply socket 230 V~
2
Output: Block 1 - refrigerator
3
Input: Block 2 - control lines, generator D+
4
Output: Block 4 - heater, safety/drainage valve, basic light (lighting in the entrance
area), entrance step
5
Output: Block 3 - panel
6
Output: Block 5 - solar cell (if fitted), spare 2, spare 3, spare 4
7
Output: Block 6 - solar charge regulator (if fitted)
8
Output: Block 7 - auxiliary charging unit
9
Output: Block 8 - consumer circuit 1, consumer circuit 2, TV, water pump, spare 1,
spare 5, spare 6
10
Battery selector switch ("Blei-Säure/Blei-Gel" (lead acid/dryfill))
11
Fuses
12
Battery cut-off switch ("Batterie Ein/Aus" ("battery On/Off"))
Summary of Contents for D-Line 2011
Page 2: ...Motorhome 02 11 0 PSL MJ11 00EN Instruction manual ...
Page 8: ...8 Motorhome 02 11 0 PSL MJ11 00EN Records 1 ...
Page 12: ...12 Motorhome 02 11 0 PSL MJ11 00EN Introduction 2 ...
Page 18: ...18 Motorhome 02 11 0 PSL MJ11 00EN Safety 3 ...
Page 32: ...32 Motorhome 02 11 0 PSL MJ11 00EN Pitching the motorhome 6 ...
Page 98: ...98 Motorhome 02 11 0 PSL MJ11 00EN Sanitary fittings 11 ...