3 Technical specifications
3.1
Homologations
3.1.1
Certifications
Tab.1
Certifications
CE certificate number
NOx class
5
Boiler type
C
13
, C
33
3.2
Technical data
3.2.1
Technical information
Tab.2
General
Potterton Assure System
15
18
Gas council numbers
47 592 54
47 592 55
Tab.3
Central heating circuit specifications
Potterton Assure System
15
18
Maximum pressure
bar
3
3
Minimum pressure
bar
0.5
0.5
Central heating temperature adjustment
°C
25/80 ± 5°
25/80 ± 5°
Tab.4
Electrical specifications
Potterton Assure System
15
18
Nominal electrical power supply voltage
V
230
230
Nominal electrical power supply frequency
Hz
50
50
Nominal power consumption when firing
W
100
100
External fuse rating
Amp
3
3
Tab.5
Other specifications
Potterton Assure System
15
18
Degree of protection against humidity (EN
60529)
IP
IPX5D
IPX5D
Boiler lift weight (dry)
kg
28.06
28.06
Dimensions (height/width/depth)
mm
H 700/W 390/D 285
H 700/W 390/D 285
Clearances (above/below casing)
front (for servicing)/(in operation)
side (left hand/right hand)
mm
mm
mm
178 / 200
450 / 5
5 / 5
178 / 200
450 / 5
5 / 5
These are MINIMUM recommended dimensions. Greater clearance will aid installation and maintenance.
3 Technical specifications
10
7678872 - Draft A - 22052017