Publication No. 5105703
17
Installation
PRF0022A
Flow
Return
Gasket & 4 Nuts
Securing
Screw
Flue Extension
(required for side
flues only)
Flue
Elbow
Red
Indicator
Sensing
Tube
Connections
Sensing
Tube
Connections
Thermostat
Bulb
Red
Indicator
Red or Pink Sensing
Tube (connect to red indicator)
Clear Sensing Tube
(no kinks in either tube)
When side fluing, slide the elbow extension
onto the elbow and ensure that it is pushed
on fully. Engage the screw from accessory
pack ‘C’ into the pre-drilled hole in the elbow
extension and screw fully home. The self
tapping screw will pierce the elbow and
secure the extension to the elbow.
When rear fluing, the elbow extension should
be discarded.
Slide the flue elbow into the flue duct and
locate the flange over the studs on the
fluehood ensuring that the sealing gasket is
in place.
Secure the elbow to fluehood using the four
brass securing nuts.
Reconnect flexible tubes to elbow, ensure
they are not kinked.
Note: Red tube connects the front aluminium
tube in upper chamber to the lower connection
on elbow, each being identified with a red
ring.
Fig. 19