© Baxi Heating UK Ltd 2012
4.0 Technical Data
4.1
Potterton Apollo 25 & 30
Flue Terminal
Diameter
100mm
Dimensions
Projection
125mm
Outercase Dimensions
Casing Height
- 780mm
Overall Height Inc Flue Elbow
- 965mm
Casing Width
- 450mm
Casing Depth
- 345mm
Weights
Packaged Boiler Carton
54.7 kg
Installation Lift Weight
47.5 kg
Central Heating Primary Circuit
Pressures
bar
Safety Discharge
3
Max Operating
2.5
Min Operating
0.5
Recommended Operating Range
1-2
DHW Circuit
bar
Pressures
Max Operating
8
Min Operating
0.15
Flow Rates
(25)
(30)
l/min
l/min
DHW Flow Rate
@ 30
o
C Rise
11.9
14.3
DHW Flow Rate
@ 35
o
C Rise
10.2
12.3
Min Working
DHW Flow Rate
2
2
Pump
Available Head
See graph below
Expansion Vessel
-
(For Central Heating
only. Integral with appliance)
bar
Min Pre-charge Pressure
0.5
(25)
( 30)
Max Capacity of
litre
litre
CH System
125
155
Primary Water Content
of Boiler (unpressurised)
3.1
3.1
Connections
copper tails
Gas Supply
-
22mm
Central Heating Flow
-
22mm
Central Heating Return
-
22mm
Cold Water Mains Inlet
-
15mm
DHW Flow
-
15mm
Pressure Relief Discharge
-
15mm
Temperatures
C.H. Flow Temp
(adjustable)
25°C to 80°C
max
(± 5°C)
D.H.W. Flow Temp
(adjustable)
35°C to 60°C
max
(± 5°C)
dependent upon flow rate
NOx Class
5
0
200
400
600
800
1000
1200
1400
0.5
1
1.5
2
2.5
3
3.5
4
Metre (wg)
Flow Rate (l/h)
Pump - Available Head
0
5
5.5
4.5
Clearances
Above Casing
200 mm Min
300mm Min (80/125)
Below Casing
200 mm Min
Front
450 mm Min
(For Servicing)
Front
5 mm Min
(In Operation)
L.H. Side
5 mm Min
R.H. Side
5 mm Min
(In Operation)
Heat Input CH (Net)
Max
Min
25 model
kW
26.06
7.82
30 model
kW
29.32
8.8
Heat Output CH (Non-Condensing)
Max
Min
25 model
kW
25.94
7.61
30 model
kW
28.63
8.56
Electrical Supply
230V~ 50Hz
(Appliance must be connected to an
earthed supply)
Power Consumption
150W
Electrical Protection
IPX0D (with timer)
IPX4D (without timer)
Internal Fuse Rating
F2L
Appliance Category
CAT I
2H
Inlet Pressure
(Natural Gas - G20)
mbar
20
Injector
(Natural Gas - G20)
6.0mm
Appliance Type
C
13
C
33
C
53
Heat Output CH (Condensing)
Max
Min
25 model
kW
26.95
8.37
30 model
kW
30.2
9.42
Heat Input DHW (Net)
Max
25 model
kW
26.06
30 model
kW
30.0
Heat Output DHW
Max
25 model
kW
24.88
30 model
kW
30.0
Max Gas Rate
(Natural Gas - G20)
(After 10 mins)
25 model
m
3
/h
2.76
30 model
m
3
/h
3.17
Condensate Drain
To accept 21.5mm (
3
/
4
in) plastic waste pipe
Heat Input CH (Gross)
Max
Min
25 model
kW
28.92
8.68
30 model
kW
32.54
9.77
Heat Input DHW (Gross)
Max
25 model
kW
28.92
30 model
kW
33.3
External Fuse Rating
3A
The efficiency is 91.0% (25)
90.1% (30)
This value is used in the UK Government’s Standard
Assessment Procedure (SAP 2005) for energy rating
of dwellings. The test data from which it has been
calculated has been certified by 0086.
SEDBUK (2005) Declaration
NOTE:
All data in this section are nominal values
and subject to normal production tolerances.
IMPORTANT:
Where Low Flow Taps or Fittings are
intended to be used in the DHW system connected it is
strongly recommended that the DHW flow rate DOES
NOT fall below 2.5l/min. This will ensure reliable
operation of the DHW function.