PROVISOIRE
NXR3i
28/08/2012 - 300029292-001-02
4.5.4
Safety valve
The safety valve must be connected to the boiler outlet and no other
valve or flap must be interposed between it and the boiler.
Minimum safety valve flowrate as a function of maximum boiler nominal output
Example
Maximum boiler nominal output is 200 kW.
Minimum safety valve flowrate must be 700 kg/h.
4.5.5
Connection of the water circuit for domestic use
Z
See: Domestic hot water calorifier instructions.
Minimum relieving capacity
Maximum gross boiler output
Unit
(a) = kW
(b) = lb/h
(c) = MBtu/h
(d) = Kg/h