Function
Prog.
no.
Level
1)
Standard value
Function input H1
None | Optg mode change HCs+DHW | Optg mode change DHW |
Optg mode changeover HCs | Optg mode changeover HC1 | Optg
mode changeover HC2 | Optg mode changeover HC3 | Heat genera-
tion lock | Error/alarm message | Consumer request VK1 | Consumer
request VK2 | Release swi pool source | Excess heat discharge | Re-
lease swi pool solar | Operating level DHW | Operating level HC1 | Op-
erating level HC2 | Operating level HC3 | Room thermostat HC1 |
Room thermostat HC2 | Room thermostat HC3 | DHW thermostat |
Pulse count | Checkb sign flue gas damper | Start prevention | Con-
sumer request VK1 10V | Consumer request VK2 10V | Preselected
output 10V
5950
C
None
Contact type H1
NC | NO
5951
C
NO
Voltage value 1 H1
5953
E
0,5
Function value 1 H1
5954
E
0
Voltage value 2 H1
5955
E
10
Function value 2 H1
5956
E
1000
Function input H4
None | Optg mode change HCs+DHW | Optg mode changeover DHW |
Optg mode changeover HCs | Optg mode changeover HC1 | Optg
mode changeover HC2 | Optg mode changeover HC3 | Heat genera-
tion lock | Error/alarm message | Consumer request VK1 | Consumer
request VK21 | Release swi pool source | Excess heat discharge | Re-
lease swi pool solar | Operating level DHW | Operating level HC1 | Op-
erating level HC2 | Operating level HC3 | Room thermostat HC1 |
Room thermostat HC2 | Room thermostat HC3 | DHW thermostat |
Pulse count | Checkb sign flue gas damper | Start prevention | Flow
measurement Hz
5970
C
None
Contact type H4
NC | NO
5971
C
NO
Frequency value 1 H4
5973
E
0
Function value 1 H4
5974
E
0
Frequency value 2 H4
5975
E
0
Function value 2 H4
5976
E
0
Function input H5
None | Optg mode change HCs+DHW | Optg mode changeover DHW |
Optg mode changeover HCs | Optg mode changeover HC1 | Optg
mode changeover HC2 | Optg mode changeover HC3 | Heat genera-
tion lock | Error/alarm message | Consumer request VK1 | Consumer
request VK21 | Release swi pool source | Excess heat discharge | Re-
lease swi pool solar | Operating level DHW | Operating level HC1 | Op-
erating level HC2 | Operating level HC3 | Room thermostat HC1 |
Room thermostat HC2 | Room thermostat HC3 | DHW thermostat |
Pulse count | Checkb sign flue gas damper | Start prevention
5977
C
None
Contact type H5
NC | NO
5978
C
NO
Function extension module 1
None | Multifunctional | Heating circuit 1 | Heating circuit 2 | Heating
circuit 3 | Solar DHW | Primary contr/system pump
6020
C
Heating circuit 2
Programming
66
Paramount three 30-115 kW
7308272-03 03.14
Summary of Contents for Paramount 40
Page 1: ...Installation manual Gas condensing boiler Paramount three 30 115 kW ...
Page 23: ...Prior to installation 7308272 03 03 14 Paramount three 30 115 kW 23 ...
Page 25: ...Fig 5 Connection plan Prior to installation 7308272 03 03 14 Paramount three 30 115 kW 25 ...
Page 28: ...4 9 Legend Prior to installation 28 Paramount three 30 115 kW 7308272 03 03 14 ...