4. Set the following parameters on the slave boiler(s).
Tab.19 Cascade configuration of the slave boilers
Parameter num
ber
Parameter
Adjustment required
Description
5710
Temps / mode CH1
Off
Deactivation of the thermostat for
terminal block M1 (1–2)
6600
Device address
2...3...4...
Cascade activation
6640
Clock mode
Slave with remote setting
Setting the slave boiler clock with a
master boiler
6.4
Controlling a boiler in 0-10 V mode
6.4.1
Electrical connection
Fig.59
Boiler in 0–10 V mode
1
2
3
4
A
ux 1-2 230 V
TA
TS
L
N
T1
T2
L
L
N
N
S1
S2
L
N
MW-3000041-05
34
AVS75
38
+
X40
X41
34 Primary pump
38 Remote control with or without room temperature
sensor
Important
Relay the pumps if the current exceeds 1 A max per output.
6.4.2
Configuring the control system
1. Go to the installer parameters.
6 Connecting diagrams and configuration
7702639 - v03 - 10072018
53