2. Insert the stripped part of the wire into the corresponding connector.
Caution
The length to be stripped must be between 10 and 12 mm.
3. Release the pressure on the spring.
The wire is attached.
4. Check that the wire is attached by pulling it gently upwards. If it comes
out of the housing, repeat step 3.
7.6.4
Description of the power supply terminal block
Fig.86
MW-1000015-06
1
2
3
4
Aux 1-2 230 V
TA
TS
L
N
T1
T2
L
L
N
N
S1 S2
L
N
2
4
6
8
5
7
1
3
1 Power supply 230 V 50 Hz
2 Power supply auxiliary circuit 1
Fig.84
MW
-3
0
0
0
0
3
8
-0
5
2
Fig.85
MW
-3
0
0
0
0
3
9
-0
4
3
7 Installation
68