10 Settings
10.1 List of parameters
10.1.1 Shortcuts menu
Tab.38 Functions accessible with the shortcut key
Parameter
Description
Adjustment range
Standby/operation
Boiler standby/Start-up.
Standby : Boiler put on standby.
The symbol is displayed.
The boiler's operating modes are deactivated.
The frost protection function is activated.
On : Putting the boiler into operation
316:Hot water boost
Forcing domestic hot water pro
duction.
On :
Activates the domestic hot water override.
The symbol
is displayed.
If a domestic hot water tank is connected to the
boiler circuit, the boiler will give priority to forcing
heating of the DHW tank, independently of the oth
er parameters.
Off : Deactivates forcing of domestic hot water.
Central heating mode CH1
Boiler operating mode.
On :
The heating is activated in Comfort mode.
The symbols ,
1 2 3
and are displayed.
Reduced:
The heating is activated in Eco mode.
The symbols ,
1 2 3
and are displayed.
Timed :
The heating operates according to the defined tim
er programs.
The symbols and
1 2 3
are displayed.
Off :
The boiler is shut down and frost protection is ac
tive.
The symbol is displayed.
Room temperature CH1
Room temperature set point in
comfort mode.
Hot water heating
Setting domestic hot water pro
duction.
On : Enables domestic hot water production.
Off :
Disables domestic hot water production.
The symbol
disappears from the display.
Eco : Not used.
Hot water temp setpoint
Domestic hot water temperature
set point.
10.1.2 Information menu
Tab.39 Information menu
Information
Description
Unit
Room temperature
Is displayed if the control system unit is configured as a room
temperature appliance
Room temperature min
Room temperature max
Boiler temperature
Boiler flow temperature
°C
Outside temp
Outdoor temperature
°C
10 Settings
7702639 - v03 - 10072018
83