Parameter number
Parameter
Description
Factory
setting
Extension
module 1
Extension
module 2
Extension
module 3
6049
6057
6065
Voltage value 1 H2 module 1
Voltage value 1 H2 module 2
Voltage value 1 H2 module 3
Definition of parameters for collector
specifications
0
6050
6058
6066
Funct value 1 H2 module 1
Funct value 1 H2 module 2
Funct value 1 H2 module 3
Definition of parameters for collector
specifications
0
6051
6059
6067
Voltage value 2 H2 module 1
Voltage value 2 H2 module 2
Voltage value 2 H2 module 3
Definition of parameters for collector
specifications
0
6052
6060
6068
Funct value 2 H2 module 1
Funct value 2 H2 module 2
Funct value 2 H2 module 3
Definition of parameters for collector
specifications
0
Tab.55 Error menu
Parameter
number
Parameter
Description
Factory set
ting
6704
Display SW
diagnostic code
Display of the software troubleshooting code:
No
Yes
Yes
6705
SW diagnostic code
Software troubleshooting code currently pending.
6706
Burn ctrl phase
lockout pos
Locking phase indicating the place where the error occurred.
6710
Reset alarm relay
Alarm relay reset.
6800
History 1
Last error that occurred.
6805
SW diagnostic code
1
Last troubleshooting code that occurred.
6806
Burner control phase
1
Last locking phase indicating the place where the error occurred.
6810 – 6996
History 2 to History
20
Fault history.
Tab.56 Service/special operation menu
Parameter
number
Parameter
Description
Factory set
ting
7045
Time since
maintenance
Resetting the boiler operating time after boiler servicing.
0 months
7130
Chimney sweep
function
Chimney sweep function:
Off
On
Off
7131
Burner output
Burner output during the chimney sweep function:
Partial load
Full load
Max heating load
Full load
7140
Manual control
Manual control function:
Off
On
Off
7143
Controller stop
function
Regulator shut-down function:
Off
On
Off
7145
Controller stop
setpoint
Set point output during the regulator shut-down function: 0 % to 100 %. 100%
10 Settings
7702639 - v03 - 10072018
95