8. Disconnect the 2 wires from the safety thermostat on the combustion
chamber door and the pin under the ignition electrode.
9. Remove the nuts holding the burner in place on the heat exchanger.
10. Remove the fan, the Venturi and the burner to access the inside of the
heat exchanger.
For more information, see
Accessing the internal boiler components, page 36
Fig.115 Disconnecting the safety thermostat
on the combustion chamber door
and the pin under the ignition
electrode
MW
-3
0
0
0
1
8
2
-0
2
8
8
Fig.116 Removing the retaining nuts
MW
-3
0
0
0
1
0
8
-0
4
9
9
Fig.117 Removing the fan, the collector and
the burner
10
MW
-3
0
0
0
1
0
9
-0
4
10 Maintenance
102
7609493 - v08 - 24072018