Parameter number
Parameter
Description
Heating circuit
1
Heating circuit 2 Heating circuit 3
506
526
546
3rd Time OFF End of timer period 3.
516
536
556
Default values Reset the timer programming parameters (Yes / No)
Tab.51 Menu Time hot water
Parameter number
Parameter
Description
560
Select days
Selecting the days or group of days for the timer program.
574
Mon-Sun
Selecting a default timer program.
561
1st Time ON
Start of timer period 1.
562
1st Time OFF
End of timer period 1.
563
2nd Time ON
Start of timer period 2.
564
2nd Time OFF
End of timer period 2.
565
3rd Time ON
Start of timer period 3.
566
3rd Time OFF
End of timer period 3.
576
Default values
Reset the timer programming parameters (Yes / No).
Tab.52 Menu Holiday Settings
Parameter number
Parameter
Description
Factory setting
Heating
circuit 1
Heating
circuit 2
Heating cir
cuit 3
641
651
661
Select
Selecting the holiday period
Period 1
642
652
662
Start
Selecting the day and month of the start of the current
holiday period.
643
653
663
End
Selecting the day and month of the end of the current
holiday period.
648
658
668
Operating
level
Boiler operating mode during the holiday period.
Off
Reduced
Off
Tab.53 Menu Temps / mode CH1 – Temps / mode CH2 – Temps / mode CH3
Parameter number
Parameter
Description
Factory setting
Heating
circuit 1
Heating
circuit 2
Heating cir
cuit 3
700
1000
1300
Operating
mode
The control unit is installed on the boiler:
Off : heating is deactivated.
Timed : heating is dependent on the timer pro
gram.
Reduced : heating is in permanent reduced mode.
On : heating is in permanent comfort mode.
The control unit is installed as a room temperature
control system:
Off : the boiler starts up when the room tempera
ture falls below the frost protection set point.
Timed : heating is dependent on the timer pro
gram.
Reduced : the room temperature set point is the
reduced set point (parameters 712, 1010, 1310)
On : the room temperature set point is the comfort
set point (parameters 710, 1010, 1310)
On
710
1010
1310
Comfort
setpoint
20°C
712
1012
1310
Reduced
temp setpoint
16°C
9 Settings
72