Product name
SIRIUS
THREE FS
50
SIRIUS
THREE FS
70
SIRIUS
THREE FS
90
SIRIUS
THREE FS
110
Standby heat loss
P
stby
kW
0.055
0.059
0.066
0.070
Ignition burner power consumption
P
ign
kW
-
-
-
-
Annual energy consumption
Q
HE
GJ
139
201
-
-
Sound power level, indoors
L
WA
dB
61
64
-
-
Emissions of nitrogen oxides
NO
X
mg/kWh 27
31
36
22
(1) Low temperature means for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C return temperature
(at heater inlet).
(2) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
See
The back cover for contact details.
3.2.2
Sensor specifications
Tab.7
Heating flow sensor and return sensor
Temperature (in °C)
30
65
85
Resistance (in ohms)
8059
2084
1070
Tab.8
Flue gas sensor
Tempera
ture (in °C)
-50
-10
0
40
100
200
250
300
Resistance
(in ohms)
1 755765
117521
67650
10569
1377
145
65
34
Tab.9
Outside sensor
Tempera
ture (in °C)
-30
-15
-5
0
10
20
30
50
Resistance
(in ohms)
13034
5861
3600
2857
1840
1218
827
407
3.3
Dimensions and connections
Fig.2
Dimensions and connections SIRIUS THREE FS 50 and SIRIUS THREE FS 70
600
440
247
848
56
681
212
420
65
905
586
555
440
371
271
147
98
173
(1)
MW-3000001-02
1
5
2
4
3
3 Technical specifications
14
7609493 - v08 - 24072018