Publication No. 559767
Fault Finding 35
Fault Finding - Page 35
S
U
P
0
1
3
4
A
Is the GREEN LED on
continuously?
Turn the Boiler Thermostat to OFF
Switch OFF External Call for heat
Is the Water Pump still running?
Does the Water Pump stop?
Replace Electronics
THE BOILER IS FULLY
FUNCTIONAL
Press RESET BUTTON
THE BOILER IS ALIGHT
Is the RED LED
Flashing?
Ensure the Gas Supply
is ON
Isolate the Electricity
Supply. Is the Overheat
Thermostat open circuit?
Whilst GREEN LED was
flashing rapidly,
was a flame visible
through the
viewing window?
After 2 further ignition attempts,
does the RED LED flash?
Is the Electrode Gap correct
(3-4mm) and Lead O.K.?
Rectify or replace the Electrode
and Lead as appropriate
Replace Overheat Thermostat
Is there 210v dc across the
outer pins of the Gas Valve
Connector, whilst the GREEN
LED is flashing rapidly? (16Hz)
Replace Gas Valve Assembly
Check Water Pump and
associated wiring
Is the Water Pump running?
NO
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Is there 230v ac on the Pump
Outlet connection of the
appliance
NO
NO
Fault Finding Guide For 30-80 Models
From
Page
1
From
Page
1
Page 2
Check LINK is made between
solenoids on the Gas
Valve Connector
Summary of Contents for Suprima 30
Page 6: ...Installation Requirements Page 6 ...
Page 10: ...Installation Requirements Page 10 Fig 3 Fig 4 ...
Page 12: ...Flue Kits Page 12 ...
Page 13: ...Optional Extras Flues Page 13 Installation instructions included as necessary with each kit ...
Page 14: ...System and Other Kits Page 14 ...
Page 15: ...System and other Kits Page 15 ...
Page 33: ...6 Wiring Diagram Page 33 ...