Lubricating the drive:
(After every 50 operating hours) with grease
• SP1
• SP
2
SP1
SP2
Gear oil:
(After every 100 operating hours)
126-16-109
62
63
The gearing is located on the innerside of the conditioner.
• Open drain plug (63) and drain oil
• Fill with gear oil (700 ml) through the refill screw (62)
(Fully synthetic lubricating oil for high-
temperature lubrication, ISO-VG class 220)
- 28 -
1700-GB_ROLLER CONDITIONER_3783
ROLLER CONDITIONER
GB