- 32 -
1700-GB CONDITIONER_3784
GB
CROSS FLOW
Maintenance
Before any cleaning or servicing activities,
park the tractor on firm, level ground and
secure against rolling.
Put the machine in the working position.
Turn off the engine and remove the
ignition key.
Wait until all moving parts have come to
a complete standstill.
Clearing blockages
WARNING
Risk of death due to the machine's weight.
Lock the servo for the lifting cylinder.
Do not crawl under the machine.
A blockage is generally found in the ejector.
Open the tailgate to be able to clear the blockage.
Check V-belt tension (if necessary)
When the tip of the bracket (1) is flush with the washer (2),
this means the V-belt tension is correct.
1
2
Replacing driving belts:
When the driving belts show signs of damage or wear,
they must be replaced. (Note: Always replace the complete
belt set!)
• Relieve belt tension by loosening the nut.
• Replace
belt
• Restore belt tension
Cleaning (every 20 hrs)
- Open the coverings and service accesses to the belt
drive.
- Remove collected debris
- Clean cross-feeding auger.
Debris can affect lubrication which can
lead to machine damage.
Lubricate angular gear (1)
every 100 operating hours.
1
- Undo drain plug (A) and drain oil
- Pour 0.8 l SAE 90 gear oil into the fill opening (B)
- Check oil quantity at oil level
A
B
Lubricate angular gear (2)
every 100 operating hours
2
- Undo drain plug (A) and drain oil
- Pour 0.8 l SAE 90 gear oil into the fill opening (B)
- Check oil quantity at oil level
510.083
62
63
OIL-LEVEL
A
B