- 39 -
GB
1601-GB MAINTENANCE_3784
MAINTENANCE
Cutter bar oil change
- Change oil after the first 50 operating hours or after
100 ha at the latest.
• Change oil when at operating
temperature.
• The oil is too viscous when cold.
Too much old oil remains stuck to the
gearwheels and thus any suspended
matter present cannot be removed from
the gearing.
• It can take some time until the used oil
has completely drained.
Oil quantity:
NOVACAT 352 ED:
3.5 litre SAE 90
- Bring mower bar to max. tilt.
- Take out oil drain plug (62), let oil run out and dispose
of waste oil correctly.
Oil change angular gear 1
- Change oil after the first 50 operating hours.
Under normal operating conditions, oil is to be
replenished annually (OIL LEVEL).
- Change oil after 100 ha at the latest.
Oil quantity:
1.25 litre SAE 90
62
63
OIL
LEVEL
1
2