0900_GB-Select Control_3843
- 17 -
GB
SELECT CONTROL
Features of the Terminal
Electrical Connection
The terminal’s electricity is supplied via a plug in accordance with DIN 9680 from the tractor’s 12 V on-board electrical system. These
3-pin plugs are also used in a 2-pin version as only the two main connections (+12 V, earth) are required.
Caution!
Plugs and sockets of a different design are not permissible as functional safety is not guaranteed.
Technical Data
Operating voltage:
+10V ......+15V
Operating temperature range:
-5°C ...... +60°C
Storage temperature:
-25°C .... +60°CL
Degree of protection:
IP65
Fuse:
10 A multi-fuse in operatingvoltageplug.
Function
The attachment is operated by way of a single-action control unit on the tractor with which the individual functions can be pre-selected
using the Select Control terminal. The pre-selected functions are indicated by means of an active LED display next to the key.
Commissioning
Position the Select Control terminal so that it is easily visible
in the tractor cab. (There is a magnet on the rear for attaching
the terminal.)
Insert plug (1) into tractor’s 12 V power supply.
Route job computer’s cable from attachment into tractor cab
and connect using plug (2).
(Ensure that the cable is routed properly!)
Press the “I/O”
key to switch on the terminal.
Keep the “I/O”
key depressed for 3 seconds to switch
off the terminal.