- 23 -
1100_GB-Power-Control_3843
POWER CONTROL - OPERATION
GB
Speed control of cross conveyor belts
With the operating method “Speed variance left and
right”, the speed between both cross conveyor belts
is changed so that one belt is always running faster
than the other.
The tortoise (slow) and hare (fast) symbols indicate the
speed of the relevant cross conveyor belt.
Speed indication is shown only when the cross conveyor
belts are in the working position.
g
Set operating method
Tick = varying speed between left and right cross
conveyor belt (for mowing in lineal contours)
Cross = Even speed for both cross conveyor belts
with the possibility of switching between two speed
rates
h
Set speed rate
Two speed rates can be set for cross conveyor
belts
Setting: in 5% intervals
Setting range: 5-100%
Note!
This menu will not be shown if the speed
control is not activated in the configuration
of machines
g
h