background image

-- 12 --

ELECTROLUX HOME PRODUCTS, INC., at
1--800--554--6723 WARRANTY PERIOD: Any
warranted part which is not scheduled for re-
placement as required maintenance, or which is
scheduled only for regular inspection to the ef-
fect of “repair or replace as necessary” shall be
warranted for 2 years. Any warranted part which
is scheduled for replacement as required main-
tenance shall be warranted for the period of time
up to the first scheduled replacement point for
that part. DIAGNOSIS: The owner shall not be
charged for diagnostic labor which leads to the
determination that a warranted part is defective
if the diagnostic work is performed at an ap-
proved ELECTROLUX HOME PRODUCTS,
INC., servicing center. CONSEQUENTIAL
DAMAGES: 
ELECTROLUX HOME PROD-
UCTS, INC., may be liable for damages to other
engine components caused by the failure of a
warranted part still under warranty. WHAT IS
NOT COVERED
: All failures caused by abuse,
neglect, or improper maintenance are not cov-
ered. ADD--ON OR MODIFIED PARTS: The
use of add--on or modified parts can be grounds
for disallowing a warranty claim. ELECTRO-
LUX HOME PRODUCTS, INC., is not liable to

cover failures of warranted parts caused by the
use of add--on or modified parts. HOW TO FILE
A CLAIM: 
If you have any questions regarding
your warranty rights and responsibilities, you
should contact your nearest authorized service
center or call ELECTROLUX HOME PROD-
UCTS, INC., at 1--800--554--6723. WHERE TO
GET WARRANTY SERVICE: 
Warranty ser-
vices or repairs shall be provided at all ELEC-
TROLUX HOME PRODUCTS, INC., service
centers.

Call:

1--800--554--6723

MAINTE-

NANCE, REPLACEMENT AND REPAIR OF
EMISSION RELATED PARTS
: Any ELEC-
TROLUX HOME PRODUCTS, INC., approved
replacement part used in the performance of
any warranty maintenance or repair on emis-
sion related parts will be provided without
charge to the owner if the part is under warranty.
EMISSION CONTROL WARRANTY PARTS
LIST: 
Carburetor, Ignition System: Spark Plug
(covered up to maintenance schedule), Ignition
Module, Muffler including catalyst. MAINTE-
NANCE STATEMENT: 
The owner is responsi-
ble for the performance of all required mainte-
nance as defined in the instruction manual.

This engine is certified to be emissions compliant for the following use:

Moderate (50 hours)

Intermediate (125 hours)

Extended (300 hours)

Summary of Contents for PPB200 LE

Page 1: ... siones graves AVERTISSEMENT Lire le manuel d instructions et bien respecter tous les avertisse ments et toutes les instructions de sécurité Tout défaut de le faire pourrait entraîner des blessures graves Instruction Manual Manual de Instrucciones Manuel d Instructions PPB2000 LE Electrolux Home Products Inc 104 Warren Road Augusta GA 30907 Copyright E2004 Electrolux Home Products Inc 530164283 2 ...

Page 2: ...s mixed poured or stored D Mix and pour fuel in an outdoor area store fuel in a cool dry well ventilated place use an approved marked container for all fuel purposes D Do not smoke while handling fuel or while operating the unit D Make sure the unit is properly assembled and in good operating condition D Do not fill fuel tank while engine is hot or running D Avoid spilling fuel or oil Wipe up fuel...

Page 3: ... antivibration system does not guarantee the avoidance of these problems Users who operate power tools on a continual and regular basis must monitor closely their physical condition and the condi tion of this tool SPECIAL NOTICE This unit is equipped with a temperature limiting muffler and spark arresting screen which meets the require ments of California Codes 4442 and 4443 All U S forest land an...

Page 4: ...tch area of the vacuum inlet Latch Area Blower Outlet Vacuum Inlet Cover Latch Area 3 Gently tilt the handle of the screwdriver to ward the back of the unit to release the latch while pulling up on the vacuum inlet cover with your other hand 4 Hold the vacuum inlet cover open until up per vacuum tube is installed Vacuum Inlet Vacuum Inlet Cover Retaining Post 5 Place the hooks of the upper vacuum ...

Page 5: ...e Throttle Lever Spark Plug Blower Tube Primer Button Rear Handle Lower Vacuum Tube Upper Vacuum Tube Vacuum Bag Elbow Tube THROTTLE LEVER The THROTTLE LEVER is used to select the desired engine speed and to stop the engine Move the throttle lever to the position for full speed operation Move the throttle lever to the position for idle speed To stop the engine move the throttle lever to the STOP p...

Page 6: ...es do not attempt to fuel your unit Call 1 800 554 6723 FUELING ENGINE WARNING Remove fuel cap slowly when refueling This engine is certified to operate on unleaded gasoline Before operation gasoline must be mixed with a good quality synthetic 2 cycle air cooled engine oil designed to be mixed at a ratio of 40 1 Poulan Weed Eater brand synthetic oil is recommended Mix gasoline and oil at a ratio o...

Page 7: ...ntil engine runs but no more than 5 pulls NOTE If engine has not started pull starter rope 5 more pulls If engine still does not run it is probably flooded 3 To stop the engine move the throttle lever to the STOP position STARTING A FLOODED ENGINE Flooded engines can be started by placing the choke lever in the RUN position Move throttle lever to the fast position then pull rope until engine start...

Page 8: ...en pull off spark plug boot 2 Remove spark plug from cylinder and dis card 3 Replace with Champion RCJ 6Y spark plug and tighten securely with a 3 4 inch 19 mm socket wrench 4 Reinstall the spark plug boot REPLACE FUEL FILTER To replace fuel filter drain unit by running it dry of fuel then remove fuel cap retainer assem bly from tank Pull filter from tank and remove it from the fuel line Install n...

Page 9: ... guards in place Position unit so that any sharp object cannot acci dentally cause injury S Store unit and fuel well out of the reach of children SEASONAL STORAGE Prepare unit for storage at end of season or if it will not be used for 30 days or more If your unit is to be stored for a period of time S Clean the entire unit before lengthy stor age S Store in a clean dry area S Lightly oil external ...

Page 10: ...Compression low Engine will not accelerate lacks power or dies under a load 1 Clean or replace air filter 2 Check for dirty fuel filter replace Check for kinked or split fuel line repair or replace 3 Clean or replace spark plug and re gap 4 Contact an authorized service dealer 5 Contact an authorized service dealer 6 Contact an authorized service dealer Engine smokes excessively 1 Choke partially ...

Page 11: ... your small off road engine for the periods of time listed below provided there has been no abuse neglect or improper maintenance of your small off road engine Your emission con trol system includes parts such as the carbure tor and the ignition system Where a warrant able condition exists ELECTROLUX HOME PRODUCTS INC will repair your small off road engine engine at no cost to you Expenses covered...

Page 12: ... for disallowing a warranty claim ELECTRO LUX HOME PRODUCTS INC is not liable to cover failures of warranted parts caused by the use of add on or modified parts HOW TOFILE A CLAIM If you have any questions regarding your warranty rights and responsibilities you should contact your nearest authorized service center or call ELECTROLUX HOME PROD UCTS INC at 1 800 554 6723 WHERE TO GET WARRANTY SERVIC...

Reviews: