3.3. Circuit Breaker
The circuit breaker (see
3
in Figure 1 on page 7) is the is equipped with a shunt trip which will
shut off the power if the cover is removed from the unit, or if the E-Stop switch is pressed.
3.4. Terminal Block # 1
The top three terminals of Terminal Block # 1 can be utilized for remote power reference..
(see
4
in Figure 1 on page 7). The lower three terminals can be used to interface the power
supply with a computer. APPENDIX A: User Interface on page 17 explains the connections in
more detail.
3.5. Terminal Block # 2
Heat On, E-Stop, Auxiliary Interlock, and Reset functions can be run remotely from this
terminal block. There are also relay contacts for Heat On, Power Supply Fault and Power
Supply ready. APPENDIX A: User Interface on page 17 explains the connections in more
detail.