4
2
3
SAFETY INSTRUCTIONS
Do not touch the nozzle or molten adhesive with
bare skin as they are hot - the operating
temperature of this tool is approximately 200°C /
392°F (LT 120°C / 248°F). Protective gloves should
always be worn. Careless handling can cause skin
burns. If molten adhesive comes into contact with
the skin, immerse the affected area immediately
in plenty of cold water. Seek medical advice if
necessary. In addition to the safety instructions
herein, any statutory regulations, local fire insurance
regulations, or other generally valid “regulations for
accident prevention” must be complied with when
using this tool.
Repairs should only be undertaken by competent
personnel with the adequate electrical knowledge.
Before proceeding with any maintenance or repair
operation, disconnect the tool from the mains
electricity supply. If in doubt, contact your supplier.
•
WARNING - This tool must be placed on its
stand when not in use; do not leave the tool
unattended when switched ON.
•
Place the tool on its stand after use and allow it to
cool down before storage.
•
Never use the tool if it is damaged in any way. If the
supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similar qualified
persons in order to avoid a hazard.
•
Do not use this tool whilst under the influence of drugs
or alcohol.
•
Do not use this tool in damp rooms, and do not expose
to rain, moisture or immerse in water.
•
Do not use this tool in the vicinity of any heat-sensitive
materials, or any flammable materials, liquids, or
gases, and do not apply to the same place for a long
time.
•
Only use extension cables with a wire cross-section of
1.5mm
²
/ 16 a.w.g. and no more than 20m / 65 ft in
length.
•
Depending on the country, this tool may be fitted with
a polarized plug, intended to be fitted into a polarized
socket. If the plug does not fit fully in the outlet, reverse
the plug. If it still does not fit please contact the
manufacturer. Do not modify the tool
’
s plug. Never pull
on the tool
’
s connecting cable.
•
This tool is not intended for the use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the tool by a person
responsible for their safety.
AVOIDING PROBLEMS
•
Ensure that tool has reached temperature before
operating.
•
Do not leave tool switched on for long periods
without use. If tool is not to be used for more than 40
minutes, switch off and restart when required.
•
Never lay the tool on its side. Always use stand
provided, the optional bench stand or the suspension
unit.
•
Only use adhesives designed for use with this tool.
•
Never remove a partially used glue stick. This can
lead to irreparable damage.
•
Hotmelt glue can be used instead of nails, staples,
tapes, and liquid glues. However they should not be
used in place of structural connections when heavy
loads are involved.
•
Do not use hotmelt glue for objects that are
exposed to extreme heat.
Do not connect to the main supply at this point!
1.
Attach the tool stand
2.
Ensure temperature module is located in its
socket
3.
Pull plunger handle fully back
4.
Insert adhesive into the breach
5.
Operate the trigger to push adhesive forward
6.
Connect to mains supply
7.
Green light illuminates
8.
Wait 5 minutes to warm
9.
Operate the trigger to push adhesive forward to the
reload position
10.
Pull handle fully back to reload more adhesive
11.
Load more adhesive and continue
12.
To switch off the tool, disconnect from the mains
supply
1
4
5
4
6
4