operation
Hammer drills require very little operator pressure. Excessive
pressure on the tool can lead to unnecessary overheating of the
motor, and burning of the driven tool.
Auxiliary handgrip
The auxiliary handgrip can be rotated 360º around the drill head, enabling
safe and comfortable operation, for both left and right-handed users.
- Loosen the handgrip by turning it anticlockwise.
- Rotate the handgrip to the desire position.
- Retighten the handgrip in the new position
Exchanging and removing drill bits
Fig. A+B
Before exchanging bits, first remove the power plug from the wall
socket.
Inspect bits regularly during use. Blunt bits should be re-sharpened
or replaced.
- Lightly oil the bit shaft before inserting it into the chuck.
- Slide the locking sleeve (10, Fig A) to the rear, and insert the bit into the
chuck opening. Ensure that the keyway in the bit is seated properly in the
chuck, by carefully turning the bit until it clicks into place. Release the
locking sleeve.
- To remove the bit, slide and hold the locking sleeve to the rear.
Keyed dril adapter
Fig. C
Use the supplied drillchuck for use with standard drills. Mount the drillchuck
as shown in the illustration.
Setting depth gauge
Fig A.
- Unscrew the screw.
- Insert the depth gauge ruler through the hole in the auxiliary handgrip.
- Slide the ruler to the desired depth.