Pre-operation check

Running the engine with persistent pinking is misuse, and the Manufacturer’s Warranty does
not cover parts damaged by misuse.

Oxygenated Fuels

Some petrols are being blended with alcohol or an ether compound to increase the octane.
These petrols are collectively referred to as oxygenated fuels. If you use an oxygenated fuel,
be sure its pump octane rating is 86 or higher.

Ethanol (ethyl or grain alcohol)

Petrol containing more than 10% ethanol by volume may cause starting and/or performance
problems.

Methanol (methyl or wood alcohol)

Petrol containing methanol must contain solvents and corrosion inhibitors to protect the fuel
system. Petrol containing more than 5% methanol by volume may cause starting and/or
performance problems and may damage metal, rubber and plastic parts of your fuel system.

MTBE (methyl tertiary butyl ether)

You may use petrol containing up to 15% MTBE by volume.

Before using an oxygenated fuel, try to confirm the fuel’s contents. Some states require this
information to be posted on the pump. If you notice any undesirable operating symptoms,
switch to a conventional unleaded petrol. Fuel system damage or performance problems
resulting from the use of an oxygenated fuel are not the responsibility of the manufacturer
and are not covered under warranty.

NOTICE
Oxygenated fuels can damage paint and plastic. Be careful not to spill fuel when
filling your fuel tank. Damage caused by spilled fuel is not covered under warranty.

16

13

Disconnecting the battery cables:

1. Stop the engine.
2. Disconnect the negative (-) battery cable from the generator negative (-) terminal.
3. Disconnect the other end of the negative (-) battery cable from the battery negative (-) 

terminal.

4. Disconnect the positive (+) battery cable from the generator positive (+) terminal.
5. Disconnect the other end of the positive (+) battery cable to the battery positive (+) terminal.
6. Connect the vehicle earth cable to the battery negative (-) terminal.
7. Reconnect the vehicle earth battery cable.

DC Circuit Protector

Earth

Terminal

DC 12

Circuit

Breaker

Helpline No. UK / Northern Ireland 08707 323023    Rep. Ireland 1800 481 005

Web Support : www.omegawolf.com/powercraft

Model Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023    Rep. Ireland 1800 481 005

Web Support : www.omegawolf.com/powercraft

Model Number: PC2800LR

Summary of Contents for PC2800LR

Page 1: ...umber given below Office hours are as follows Mon Fri 8 00am 6 00pm Saturday 8 00am 2 00pm Sunday 10 00am 4 00pm Omega Wolf Ltd Prospect Close Lowmoor Business Park Kirkby In Ashfield Nottinghamshire NG17 7LF UK UK NORTHERN IRELAND 08707 323023 REPUBLIC OF IRELAND 1800 481 005 www omegawolf com powercraft Name Address Contact Telephone No Email Location of purchase Fault Description 2 800W DUAL VO...

Page 2: ...f the date of purchase The guarantee period can only be extended for the duration of any repair required During the warranty period defective devices can be sent FREIGHT PREPAID to the service address stated at the end of this booklet We will at our discretion either repair or exchange the device in accordance with warranty legislation Please include the following when sending in your product for ...

Page 3: ...and without incurring any obligation No part of this publication may be reproduced without written permission Safety Message Your safety and the safety of others are very important We have provided important safety messages in this manual and on the generator Please read these messages carefully Specification MODEL PC2800LR Max Output Watts 2800 Cont Output Watts 2500 Phase Single Rated Voltage 23...

Page 4: ... Be sure that anyone who operates the generator receives proper instruction Do not let children operate the generator SAFETY INFORMATION Generators are designed to give safe and dependable service if operated according to instructions Read and understand this user s manual before operating your generator You can help prevent accidents by being familiar with your generator s controls and by observi...

Page 5: ...omes very hot during operation and remains hot for a while after stopping the engine Be careful not to touch the silencer while it is hot Let the engine cool before storing the generator indoors Petrol is extremely flammable and is explosive under certain conditions Do not smoke or allow flames or sparks where the generator is refueled or where petrol is stored Refuel in a well ventilated area wit...

Page 6: ...etrol and add some petrol conditioner Drain the carburetor float bowl Drain the fuel sediment bowl Remove the spark plug Put a tablespoon of engine oil into the cylinder Turn the engine slowly with the pull rope to distribute the oil Reinstall the spark plug Change the engine oil After removal from storage drain the stored petrol into a suitable container and fill with fresh petrol before starting...

Page 7: ...move the spark plug 4 Visually inspect the spark plug Discard it if the insulator is cracked or chipped Clean the spark plug with a wire brush if it is to be reused 5 Measure the plug gap with a feeler gauge Correct as necessary by carefully bending the side electrode The gap should be 0 70 0 80 mm 0 028 0 031 in 6 Check that the spark plug washer is in good condition and thread the spark plug in ...

Page 8: ...arm water then rinse thoroughly or wash in nonflammable or high flash point solvent Allow the element to dry thoroughly 3 Soak the element in clean engine oil and squeeze out the excess oil The engine will smoke during initial start up if too much oil is left in the element 4 Reinstall the air filter element and the cover Fuel Sediment Bowl Cleaning The sediment bowl prevents dirt or water which m...

Page 9: ...ug securely 3 Refill with the recommended oil and check the level Oil capacity 0 6 Litres Oil Alert System The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe limit the Oil Alert system will automatically shut down the engine the engine switch will remain in the ON position Pi...

Page 10: ...ptacles The system earth is not connected to the AC neutral wire The earth terminal can be used to earth the generator or bond the frame of the generator to the frame of a vehicle but only if it is required by local law or electrical code Before using the earth terminal consult a qualified electrician or electrical inspector for regulations Maintenance Periodic maintenance and adjustment is necess...

Page 11: ...used for no more than 5 minutes NOTICE Substantial overloading will trip the circuit breaker Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit breaker OFF but will shorten the service life of the generator Limit operation requiring maximum power to 5 minutes Maximum power is See specifications For continuous operation do not excee...

Page 12: ...ill trip the DC circuit protector PUSH button extends out If this happens wait a few minutes before pushing in the circuit protector to resume operation If the circuit protector continues to go OFF discontinue charging and contact the helpline Generator Use Starting the engine STARTING THE ENGINE 1 Make sure to disconnect all electrical loads from panel receptacles The generator may be difficult t...

Page 13: ...notice any undesirable operating symptoms switch to a conventional unleaded petrol Fuel system damage or performance problems resulting from the use of an oxygenated fuel are not the responsibility of the manufacturer and are not covered under warranty NOTICE Oxygenated fuels can damage paint and plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spilled fuel is not ...

Page 14: ... sure the tank cap is closed properly and securely Be careful not to spill fuel when refueling Spilled fuel or fuel vapour may ignite If any fuel is spilled make sure the area is dry before starting the engine Avoid repeated or prolonged contact with skin or breathing of vapour KEEP OUT OF REACH OF CHILDREN Fuel tank capacity 15 Litres Use petrol with a pump octane rating of 86 or higher We recomm...