Model Number: PGG-800
Assembling and operations
Before starting the generator
Ground terminal
The generator ground terminal is connected to the frame of the
generator, the metal non-current-carrying parts of the generator,
and the ground terminals of each receptacle. Before using the
ground terminal, consult a qualified electrician, electrical inspector
or local agency having jurisdiction for local codes or ordinances
that apply to the intended use of the generator.
Assembly
Unscrew the tank cover. Remove the measuring jug and fit it into the recess
on the bottom of the tank cover. Screw the tank cover back onto the tank.
Use the enclosed screws to fasten the carry handle onto the tank.
Important!
Before use, the tank needs to be filled up with a petrol mixture
in a mixing ratio of 50:1. Refer to the table below.
Use the measuring jug inside the tank. One increment equals 20ml. Mix the
mixture well.
Mixture 50:1
Regular unleaded petrol 2 stroke oil
1l
20ml
2l
40ml
3l
60ml
4l
80ml
For general use you can use 2-stroke oil.
Filling up the tank
• Use petrol mixture only
• Remove any powercords
• Turn power switches off
• Do not overfill – leave air gap at top of fuel level
• Always screw down fuel cap
• Clean up any spilled fuel
• Do not smoke while operating the generator
Always use caution!