TROUBLESHOOTING
Symptom
Problem
Solution
Intermittent spray
• Presence of air in the paint circuit.
• Tighten the nozzle using the wrench
provided.
• Make sure that the tank is empty.
• Check that the connecting hole is not
obstructed.
• Tighten the gland screw or replace the
gasket if worn.
Pattern arched
• Material residue in the holes obstructs
the passage of material.
• The nozzle is dirty or malfunctioning.
• The atomization cap is dirty or
damaged.
• Submerge the head in solvent.
• Clean and open all closed holes with a
jet or compressed air or a toothpick.
• Do not use pointed metal objects, or
you may deform the hole of the head
part.
Uneven pattern
• Material builds up on the outside of
fluid nozzle tip, or center hole, or
partially clogged nozzle orifice.
• Loose fluid nozzle.
• Clean the head and nozzle.
• Make sure that the centering between
the two is precise.
• Check the tip of the pin is not ruined.
• Replace the nozzle and the head.
The center of the pattern is too narrow
• Atomization of air pressure is too high
• Material too thin
• Reduce the quantity of air and increase
the flow of paint.
Poor atomization / Spray concentrated
into the centre
• The flow of paint is greater than the
pressure and quality of air supplied.
• Clean the head and the nozzle.
• Make sure that the paint is not too
dense and dilute if necessary.
Little or no paint output
• Fluid passage is clogged with dirt.
• Air holes in the cover are blocked.
• Fluid needle stroke is small.
• Remove obstructions.
• Adjust fluid needle stroke.