14.4V Cordless Grease Gun
8
For technical questions call: 1-800-665-8685
V 3.03
8505547
MAINTENANCE
1. Make sure the trigger switch is in the OFF position, the battery is removed from the
grease gun, and the charger is unplugged from the electrical outlet before performing any
inspection, maintenance, or cleaning.
2. Check the general condition of the grease gun before each use. Check for misaligned or
binding moving parts, cracked or broken parts, leaking battery packs, damaged hoses, and
any other conditions that may affect the safe operation of the grease gun. If abnormal noise
or vibration occurs, have the problem corrected before further use. Do not use
damaged equipment.
3. Daily maintenance: Use a soft, dry cloth to remove all dirt, grease, and debris from the
exterior of the grease gun. Do not use solvents to clean the grease gun.
4. Use only identical replacement parts when servicing. Only use accessories that are intended
for use with this tool.
5. If repairs are required, bring your tool to an authorized service centre.
STORAGE
When storing, always remove the battery pack from the grease gun. Keep the grease gun and its
accessories in a clean, dry location and out of the reach of children.
DISPOSING OF THE TOOL
1. If your tool has become damaged beyond repair, do not throw it out. Bring it to the
appropriate recycling facility.
2. Do not incinerate battery packs. Battery packs may explode when exposed to high heat.
TROUBLE SHOOTING
Problem(s)
Possible cause(s)
Suggested solution(s)
Motor does not run.
1. Battery discharged
2. Faulty wiring
1. Recharge the battery.
2. Take the unit to a qualified
service centre.
Pressure relief valve
remains open.
1. Blockage in the line or the
grease fitting.
1. Check the hose and the
grease fitting.
2. Remove and clean
Gun does not
dispense grease.
1. Grease tube is empty.
2. Air in the pump.
1. Refill the grease tube.
2. Purge the air pockets or re-
prime the gun
Continuous loss of prime.
1. Air pockets
2. Plunger is binding in the
grease tube assembly.
3. Worn or faulty
pump piston.
1. Empty the grease tube
assembly, refill,
and re-prime.
2. Take the unit to a qualified
service centre.