background image

8717035 

115V Mini Utility Pump 

V1.0 

For technical questions call 1-800-665-8685 

SPECIFICATIONS 

Max. Flow Rate 

330 GPH 

Horsepower 

1/10 HP 

Frequency Rating 

60Hz 

Current Rating 

2.2A 

Discharge 

3/4 in. GHT 

Max. Suction Lift 

3 ft 

Max. Discharge Head 

27 ft 

Operating Temperature Range 

0 to 45ºC 

Housing Material 

Powder Coated Carbon Steel 

Impeller Material 

NBR Rubber 

Flow Rate @ 5 Ft 

300 GPH 

Flow Rate @ 10 Ft 

280 GPH 

Flow Rate @ 15 Ft 

240 GPH 

Cord Length 

6 ft 

Contents 

Suction Strainer with 6 ft Water Hose 

 

Service Kit with Impeller and Gasket 

HAZARD DEFINITIONS 

Please familiarize yourself with the hazard notices found in this manual. A 
notice is an alert that there is a possibility of property damage, injury or 
death if certain instructions are not followed. 
DANGER! 

This notice indicates an immediate and specific hazard that will 
result in severe personal injury or death if the proper 
precautions are not taken. 

WARNING! 

This notice indicates a specific hazard or unsafe practice that 
could result in severe personal injury or death if the proper 
precautions are not taken. 

CAUTION! 

This notice indicates a potentially hazardous situation that may 
result in minor or moderate injury if proper practices are 
not taken. 

NOTICE! 

This notice indicates that a specific hazard or unsafe practice will 
result in equipment or property damage, but not personal injury. 

Summary of Contents for 8717035

Page 1: ...V1 0 8717035 Please read and understand all instructions before use Retain this manual for future reference 115V...

Page 2: ...urself with the hazard notices found in this manual A notice is an alert that there is a possibility of property damage injury or death if certain instructions are not followed DANGER This notice indi...

Page 3: ...n well lit and free of distractions Place lights so you are not working in a shadow 2 Keep anyone not wearing the appropriate safety equipment away from the work area 3 Store unused tools properly in...

Page 4: ...use the tool if any parts are damage broken or misplaced Repair or replace the parts 3 Do not insert a finger or any object into the pump or motor openings 4 Do not pump hot liquids This will overhea...

Page 5: ...ccessories or when not in use 2 Protect yourself against electric shocks when working on electrical equipment Avoid body contact with grounded surfaces There is an increased chance of electrical shock...

Page 6: ...ve a rated residual current of 30 mA or less 2 Do not operate this device if the power cord is frayed or damaged as an electric shock or surge may occur resulting in personal injury or property damage...

Page 7: ...injury Remove the parts and accessories from the packaging and inspect for damage Make sure that all items in the Identification Key are included IDENTIFICATION KEY A Brush Cap B Spring Assembly C Fac...

Page 8: ...d before use to prevent damage to its mechanism 1 Prime the pump by filling the pump cavity with water through the inlet H Ensure that the impeller G is fully submerged 2 Dip the inlet hose into the w...

Page 9: ...ulling them away from the brush holders 3 Install the new brushes Ensure they are properly aligned 4 Reinstall the spring assemblies and caps REPLACING THE IMPELLER 1 Remove the face plate screws C fa...

Page 10: ...e device Problem s Possible Cause s Suggested Solution s Pump does not prime or does not retain prime during operation 1 Suction lift is too high 2 Hose is kinked 3 Hose fitting is loose 4 Hose is lea...

Page 11: ...ler is clogged or faulty 3 Hose is too long 1 Straighten 2 Remove obstruction or replace 3 Reduce length Pump does not run 1 Pump has no power 2 Impeller is clogged or faulty 3 Motor has overheated an...

Page 12: ...V1 0 8717035 Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard 115 V...

Page 13: ...tanch it D FINITIONS DE DANGER Veuillez vous familiariser avec les avis de danger qui sont pr sent s dans ce manuel Un avis est une alerte indiquant qu il existe un risque de dommage la propri t de bl...

Page 14: ...ions de base lorsqu il utilise cet outil afin de r duire le risque de blessure ou de dommage l quipement Conservez ce manuel qui contient les avertissements de s curit les pr cautions les instructions...

Page 15: ...ou attach s 3 N utilisez pas l outil si vous devez tirer les bras pour vous en servir Une stabilit et un quilibre appropri s sont n cessaires afin d avoir un meilleur contr le en cas de situations in...

Page 16: ...cavitation l int rieur du m canisme de la pompe et peut endommager la pompe et la rendre impossible r parer 8 Prot gez la pompe contre les temp ratures extr mes et l humidit pour pr venir toute bless...

Page 17: ...int rieur d un appareil le risque de choc lectrique devient beaucoup plus grand 4 Ne modifiez aucune partie de l appareil ou des accessoires Toutes les pi ces et tous les accessoires sont con us avec...

Page 18: ...ue dans un endroit humide l emploi d un tel interrupteur de circuit diminue le risque de choc lectrique 2 N utilisez pas cet appareil si le cordon d alimentation est effil ou endommag car un choc lect...

Page 19: ...s de chaque c t du cordon d alimentation pour cr er un couloir protecteur D BALLAGE AVERTISSEMENT Ne faites pas fonctionner l outil si des pi ces sont manquantes Remplacez les pi ces manquantes avant...

Page 20: ...ifice de refoulement de la pompe E Le tuyau de refoulement doit tre aussi court que possible et ne doit pas d passer 25 pi 2 Installez la pompe sur une surface stable de niveau s che et non glissante...

Page 21: ...lez ce que l tiquette et la plaque signal tique demeurent intactes sur l appareil Elles comportent des renseignements importants Si elles sont illisibles ou manquantes communiquez avec Princess Auto L...

Page 22: ...le l g re pour lubrifier l appareil Les autres lubrifiants pourraient ne pas convenir et risqueraient d endommager l appareil ou de causer un mauvais fonctionnement durant l utilisation AVIS N utilise...

Page 23: ...d fectueuse 5 L orifice d entr e est obstru 1 Amorcez la 2 Changez la position de la pompe 3 Redressez le 4 Remplacez la 5 Retirez l obstruction Le moteur devient trop chaud 1 La tension est incorrec...

Page 24: ...e ne fonctionne pas 1 La pompe n est pas aliment e en courant 2 La turbine est bloqu e ou d fectueuse 3 Le moteur a surchauff et le syst me de protection thermique s est d clench 1 V rifiez la source...