V1.0
1/2 HP Non-Submersible Transfer Pump
8940041
Visit www.princessauto.com for more information
9
7.
Check that the power switch is OFF and plug the pump into an outlet,
preferably a GFCI protected electrical outlet.
8. The pump will take up to 5 minutes to self-prime. An option to reduce
the wait time is to manually prime the pump
a.
Unplug the pump from the power source.
b. Remove priming plug (F) from top of the pump. Fill pump with
clean water up to top of discharge outlet. Replace priming plug.
c.
Plug the pump back into power source and turn on.
d. If water still isn’t flowing, prime the pump again. Also consider
moving the pump closer to the water and/or using a shorter inlet
hose.
9. The pump’s thermal overload device will trigger automatically when
the pump’s temperature exceeds the upper range. Turn off and unplug
the pump and allow to cool. Once cooled, it may be reused without
resetting.
10. Rinse the pump and hoses out with clean water after transferring dirty
water or water from a natural source. This will clean out grit, sand and
other particulate matter that can damage the pump.
EXTENSION CORD
Increasing an extension cord’s length
requires a heavier wire gauge. Always
use the shortest extension cord with
the thickest wire gauge for the task.
CARE & MAINTENANCE
1.
Maintain the tool with care. A tool in good condition is efficient, easier
to control and will have fewer problems.
2. Inspect the tool components periodically. Repair or replace damaged or
worn components. Only use identical replacement parts when servicing.
3. Maintain the tool’s labels and name plates. These carry important
information. If unreadable or missing, contact Princess Auto Ltd. for
replacements.
WARNING! Only qualified service personnel should repair the tool. An
improperly repaired tool may present a hazard to the user and/or others.
Extension Cord (3-prong ground)
Wire Gauge 18 16 14
12
Length (ft)
25 50 100 150