background image

16

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com

PFEH  

 

 

  

 

 

 

 

     Submersible Effluent Pumps

LIMITED WARRANTY

Manufacturer warrants, to the immediate purchaser and subsequent initial owner during the warranty period, 
every new pump to be free from defects in material and workmanship under normal use and service, when properly 
used and maintained, for a period of eighteen (18) months from date of manufacture or twelve (12) months from 
date of installation (which ever comes first). Failure due to wear due to excessive abrasives is not covered. The 
initial owner is the purchaser who first uses the pump after its initial installation, or for non-permanent installation, 
the first owner who uses the pump. The date of installation shall be determined by a dated sales receipt noting the 
model and serial number of the pump. The dated sales receipt must accompany the returned pump. Product will be 
repaired, replaced or remanufactured at Manufacturer’s option. No allowance will be made for shipping charges, 
damages, labor or other charges that may occur due to product failure, repair or replacement. This warranty does 
not apply to and there shall be no warranty for any material or product that has been disassembled without prior 
approval of Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident or act of God; that has 
not been installed, operated or maintained in accordance with Manufacturer’s installation instructions; that has 
been exposed to outside substances including but not limited to the following: sand, gravel, cement, mud, tar, 
hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive substances, wash 
towels or feminine sanitary products, etc. in all pumping applications. The warranty set out in the paragraph above 
is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other person 
to assume for us any other liability in connection with our products. Contact Manufacturer at:  1-877-24PUMPS or 
www.powerflopumps.com, Attention: Customer Service Department, to obtain any needed repair or replacement 
of part(s) or additional information pertaining to our warranty. 

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL
DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS 
FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE 
EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply 
to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above 
limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have 
other rights which vary from state to state.

Summary of Contents for PFEH Series

Page 1: ...877 24PUMPS www powerflopumps com 0 5 1HP 3450 RPM 60 Hz Submersible Effluent Pumps ISP No PFEH 1 2021 INSTALLATION SERVICE PARTS MANUAL Series PFEH512 PFEH1022 PFEH1032 PFEH1042 ...

Page 2: ...th power connected Always wear eye protection when working on pumps Do not wear loose clothing that may become entangled in moving parts Pumps build up heat and pressure during operation Allow time for pumps to cool before handling or servicing This pump is not intended for use in swimming pools or water installations where human contact with pumped fluid Pumps when used as a decorative water foun...

Page 3: ...cal Oil Filled Silicon Carbide Silicon Carbide Buna N UPPER BEARING Single row ball oil lubricated LOWER BEARING Single row ball oil lubricated POWER CORD 15 Ft Cord Pressure Grommet for Sealing and Strain Relief MOTOR NEMA Design L Single Phase NEMA B Three Phase Class B Insulation SINGLE PHASE Permanant split capacitor Includes overload protection in motor THREE PHASE Requires overload protectio...

Page 4: ...4 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com PFEH Submersible Effluent Pumps Dimensions Performance ...

Page 5: ...below the frost line If this is not feasible remove the check valve and size the basin to accommodate the additional backflow volume Discharge Piping Discharge piping should be as short as possible and sized no smaller than the pump discharge Do not reduce the discharge pipe size below that which is provided on the pump Both a check valve and a shut off valve are recommended for each pump The chec...

Page 6: ...d Perform the following checks when pump is removed from operation or when pump performance deteriorates a Inspect motor chamber for oil level and contamination b Inspect impeller and body for excessive build up or clogging c Inspect motor and bearings d Inspect seal for wear or leakage Servicing NOTE Item numbers in refer to Figure 6 Cooling Oil Anytime the pump is removed from operation the cool...

Page 7: ... 2 To reassemble clean the threads with thread locking compound cleaner Apply removable Loctite 242 or equivalent to shaft threads Screw impeller 2 onto the shaft hand tight while using a screwdriver in the slot at the end of the shaft to hold it stationary Install impeller nut 10 and tighten Rotate impeller to check for binding Position gasket 12 on volute flange and position impeller and motor ho...

Page 8: ...is lined up on rotating member 5b and not cocked or resting on bellows tail Place conduit bushing 25 and washer 26 onto shaft Slide rotor shaft 6 with bearing 7 and seal 5 into seal plate 3 until bearing 7 seats into seal plate Locate washer 26 into place on bearing and tighten conduit bushing 25 onto seal plate 3 Place stator 6 over rotor 6 lining up motor bolts with holes in seal plate 3 Positio...

Page 9: ... Cable Motor Lead Number Green Ground Green Black 1 7 Red 2 8 White 3 9 4 5 6 Together Power Cable Motor Lead Number Green Ground Green Black 1 Red 2 White 3 4 7 Together 5 8 Together 6 9 Together Figure 5 Service PFEH Submersible Effluent Pumps Figure 5 115 230 Volt AC 1Ph Models PFEH512 PFEH1022 Figure 5 230 Volt AC 3Ph Models PFEH1032 Figure 5 460 Volt AC 3Ph Models PFEH1042 ...

Page 10: ... 877 24PUMPS www powerflopumps com Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 6 PFEH Submersible Effluent Pumps ...

Page 11: ...g PF31020008 8 4 Screw 5 16 18 x 1 1 2 Lg Stainless 9 4 Lock Washer 5 16 Stainless 10 1 Impeller Nut 1 2 Stainless 11 1 Gasket 27269 PF92010082 12 1 Gasket 27344 PF92010147 13 1 V ring 56789 PF92010111 14 1 Spacer PF92010086 15 2 Soc Hd cap screw 1 4 x 3 4 Lg Stainless 16 1 Pipe Plug 3 4 NPT 17 1 Lifting bail PF31120002 18 1 Power cable Assembly 14 3 SJTOW For 1 2 1 Hp 1 Ph Includes 19 20 21 PF091...

Page 12: ...Effluent Pumps 25 1 Conduit Bushing PF31190022 26 1 Washer Bushing PF91010053 27 2 6 Female Connector 1Ph 3Ph PF94010041 28 8 Gal Cooling Oil See Chart on Page 7 Aquire Locally 29 1 Capacitor PF31030031 30 1 Clamp PF93010001 31 1 Wire Connector PF94010011 OVERHAUL KIT Kit to include shaft seal 5 bearing 7 impeller nut 10 gasket 11 gasket 12 v ring 13 spacer 14 conduit bushing 25 washer 26 PFEH OHK...

Page 13: ...p may be required Consult the factory Disconnect unit electrically Remove the pump from the basin Detach the pump base and clean the area around the impeller Rotate impeller by hand Reassemble and reinstall Pump will not turn off Level control s unable to move to the turn OFF position due to interference with the side of basin or other obstacle Defective level control Posistion the pump or level c...

Page 14: ...14 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Notes PFEH Submersible Effluent Pumps ...

Page 15: ...15 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Notes PFEH Submersible Effluent Pumps ...

Page 16: ...t has not been installed operated or maintained in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocarbonderivatives oil gasoline solvents etc orotherabrasiveorcorrosivesubstances wash towels or feminine sanitary products etc in all pumping applications The w...

Reviews: