background image

7

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com

Trouble Shooting

Symptom

Possible Cause(s)

Corrective Action

Pump won’t start

Power supply is not connected

Check the fuse/circuit breaker or 

the power connection

Capacitor is damaged

Change capacitor

Motor blockage

Check that rotor shaft rotates 

freely.

There is noise in the 

system

The pump flow is too high

Reselect pump

Air in the system

Vent the system

The pump head is too high

Reselect pump

Noise in the pump

Air in the pump

Vent the pump

Cavitation due to insufficient 

inlet pressure

Increase system pressure within 

permissible range

Wet Rotor Circulator Pumps   

PFWRC66B1S

OPTIONAL:  PFDT - 7-Day Digital Timer

The digital, programmable timer allows for control of the circulator 

(on / off) at designated times (up to four custom settings per 24 hour 

period) for up to 7 days (similar to a programmable thermostat). The 

timer is plugged into a standard wall outlet and the circulator pump is 

then plugged into the timer allowing for time control of the pump. This 

unit has an internal battery backup which will, in the event of loss of AC 

power, power the unit and save / maintain program settings (battery will 

last for 48 hours before needing to be recharged). 

NOTE: The Digital timer (PFDT) and Aquastat (PFSOA) can ALSO be used 

together, in tandem to allow for BOTH temperature AND time control.

OPTIONAL:  PFSOA - Snap on Aquastat

The Aquastat simply “clips” onto any material 1/2” ID or 3/4” ID piping. It 

then plugs into a standard wall outlet. You would then plug in the power 

cord for the circulator into the aquastat plug and it will turn the circulator 

on and off automatically at fixed set points (ON 98°F and OFF at 114°F) 

allowing for temperature control of pump. 8 Ft. Cord.

 

NOTE: The Digital Timer (PFDT) and Aquastat (PFSOA) can ALSO be 

used together, in tandem to allow for BOTH temperature AND time 

control.

PFFP - Copper Multi Fitting Pack

Pack includes; 

Two (2) 1/2” SW x FNPT, 

Two (2) 3/4” SW x FNPT,

Two (2) 3/4” SW x 1/2” SW Reducing Bushings,

Two (2) 3/4” Street Hub Copper Union

NOTE: Used with Power-Flo Pumps Model 

PFWRC66B1S circulator pump.

Summary of Contents for PFWRC66B1S

Page 1: ...werflopumps com ISP No PFCirc66B1S 9 2020 OWNER S MANUAL PFWRC66B1S Wet Rotor Circulator Pumps For Indoor Use Only Maintenance Free Power Flo Pumps Systems Your Power Ful partner for all your pumping...

Page 2: ...or certain chemical additives to the system voids the warranty Pumps build up heat and pressure during operation Allow time for pumps to cool before handling or servicing Features These Power Flo Pump...

Page 3: ...otor Ciculator Shut Off Head ft Max Flow Gal C Cast Iron B Lead Free Bronze S Stainless Steel 1 115 V 2 230V 1P F Flanged S Copper Sweat U Union EXAMPLE PFWRC2120C1F Power FloPumps WetRotorCirculator...

Page 4: ...t Pressure ft 5 4 5 3 psi 2 2 1 9 1 3 In a pressurized system the required inlet pressure is the minimum allowable system pressure In a system open to the atmosphere the required inlet pressure is the...

Page 5: ...rical This pump will come equipped with a 6 Ft long soft jacketed 3 prong electric cord and strain relief connection for outlet plug in installations The pump must be within 6 foot of a 115 volt recep...

Page 6: ...culator Pumps Figure 2 Hot Water Line Cold Water Line PFWRC66B1S Circulator Pump ONLY Hot Water Tank Remove Drain valve from Hot Water Tank insert a tee and reinstall drain valve into tee Insert a tee...

Page 7: ...or pump is then plugged into the timer allowing for time control of the pump This unit has an internal battery backup which will in the event of loss of AC power power the unit and save maintain progr...

Page 8: ...including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances wash towels or feminine...

Reviews: