background image

Remove the input power lead from your computer and connect this to the AC “Input Power”. 
Connect one end of the Output Cable provided to a Battery Backed Outlet, and the other to your 
computer. 
Remove your telecommunications equipment lead from the apparatus and connect to the TEL/FAX 
protector. Using the lead provided connect from the additional TEL/FAX protector port to your 
apparatus. (NOTE: This is to provide surge protection on telephony lines and is not required for 
operation of the UPS). 
Connect the USB lead provided to the USB port and the other to a spare USB port on your computer 
(NOTE: This is to for software shutdown features – you do not need to install the software for the UPS 
to operate). 
Install the software on your Windows or Linux based computer following the instructions provided. 
The serial number you are required to enter is the serial number on the software sleeve – not the UPS 
serial number.

 

 

To switch on, press the ‘POWER SWITCH’ button on the front of the UPS. The UPS will emit an 
audible alarm to confirm. 
If mains power is present the GREEN LED will be illuminated and the UPS will be providing power in 
AC Mode. 
If no mains power is present the RED LED will be illuminated and the UPS will be providing power 
from its batteries in BATTERY Mode. 
When operating in AC Mode the UPS will constantly trickle charge the battery and the YELLOW LED 
will be illuminated.  
If the unit is operating in BATTERY MODE and no load (or a very light load) is connected the UPS will 
automatically switch off after 1 minute. This is to protect the batteries against deep discharge. 
To switch off, press the ‘POWER SWITCH’ button on the front of the UPS. 

 

YELLOW 
LED 

GREEN 
LED 

RED LED 

UPS STATUS 

ON 

OFF 

OFF 

AC Normal, UPS Off, Charging Battery 

ON 

ON 

OFF 

AC Normal, UPS ON in AC Mode. Charging Battery 

OFF 

OFF 

BLINKING  AC Abnormal, UPS ON in BATTERY Mode 

OFF 

OFF 

ON 

Low Battery Voltage (UPS about to shut off), UPS Overloaded 
(Remove connected load). Short Circuit (Remove fault) 

OFF 

OFF 

OFF 

UPS switched off, or auto switch off after discharge. 

 

Buzzer 

UPS Status 

No Beeps 

UPS Normal 

Beeps once per 5 seconds 

AC Abnormal, UPS in BATTERY Mode 

Beeps twice every other second 

Battery Voltage Low 

Beeps 4 times every 2 seconds 

UPS Overloaded (Remove connected load) 

Beeps Continuously 

UPS Fault / ShCort Circuit 

 

TROUBLESHOOTING 

OPERATION 

INSTALLATION 