4
MAINTENANCE AND STORAGE
Before performing maintenance, the log splitter must be placed in maintenance mode.
1.) Turn off engine.
2.) Release the control valve handle to relieve hydraulic pressure.
After performing maintenance, make sure all guards, shields, and safety features are put back
in place. Failure to follow this warning can result in serious injury.
Refer to the engine owner’s manual for engine maintenance.
What
When
How
Hoses
Each Use
Inspect for exposed wire mesh and leaks. Replace
all worn or damaged hoses before starting engine
Hydraulic Fittings
Each Use
Inspect for cracks and leaks. Replace all damaged
fittings before starting engine
Nuts and Bolts
Each Use
Check for loose bolts
Rail plate
Each Use
Apply grease to rail plate surface
Moving Parts
Each Use
Clear debris
SPECIFICATIONS
!
!
!
Splitting force……………….
Maximum Flow ………………….
Hydraulic Fluid Capacity ………..
Hydraulic Fluid Type …………….
Maximum Towing Speed…………
Maximum Log Length …………...
Hydraulic Cylinder Bore …………
Hydraulic Cylinder Stroke ……….
Maximum Log Diameter ………...
15TON
2.5GPM
5Liter
10wt AW32, ASLE
H-150, or ISO32
10MPH
20"
3"
19"
14"