background image

8

2) There is a risk of explosive gases being released when batteries are charged

or discharged, failure to follow instructions may cause property damage,
explosive hazard, and/or personal injury.

3) Always use protective eyewear when using this product; contact with battery

acid may cause blindness and/or severe burns.

4) Keep out of children’s reach.
5) ALWAYS store battery clamps in built-in storage well when not in use, and

never touch battery clamps together, this can cause dangerous sparks, power
arcing and/or explosion.

FIRST AID

SKIN: If battery acid comes in contact with skin, rinse immediately with water,
then wash thoroughly with soap and water.  If redness, pain, or irritation occurs,
seek immediate medical attention

EYES: If battery acid comes in contact with eyes, flush eyes immediately for a
minimum of 15 minutes and SEEK IMMEDIATE MEDICAL ATTENTION

3. CHARGING/RECHARGING

For maximum battery life, we recommend the Jump Start System be kept fully
charged at all times. If the battery is allowed to remain in a discharged state, 
battery life will be shortened. 

NOTE: 

Recharging battery after each use will prolong battery life; frequent 
discharges between recharges will reduce battery life.

IMPORTANT:

MAKE SURE ALL SWITCHES ARE TURNED OFF DURING RECHARGING

Charge unit for full 48 hours using AC method, prior to first use

Recharge unit fully after each use

Recharge unit once a month when not in use

3.1 120 Volt AC Charging

NOTE: 

The unit cannot be overcharged using the AC method. 

1) Simply plug the AC plug of the AC/DC adapter/charger into any standard

120 volt AC wall outlet (Figure 2A).

2) Plug the barrel connector attached to the AC/DC adapter into the small barrel

receptacle on the jump-starter that is marked recharge port.

2.1 Easy Step-by-Step Jump-Starting Instructions

This jump-starter is equipped with a manual ON/OFF power switch. The
ON/OFF power switch works in conjunction with an audible reverse polarity
alarm and a red LED. Do not turn switch to ON if the Reverse Polarity LED is lit
or alarm sounds. If inadvertent reverse polarity occurs, the alarm will sound and
the red LED will light. Disconnect the black clamp (negative clamp) first, then the
red clamp. Reconnect the polarity properly and then turn the key. To recap:

CONNECT – Red clamp first, then black clamp.

DISCONNECT – Black clamp first, then red clamp.

1) Turn OFF vehicle ignition and all accessories (radio, A/C, lights, cell phone,

etc.). Place vehicle in park and set the emergency brake. 

2) Remove booster clamps from storage location (Figure 1): simply squeeze the handles

and pull up on the clamp. 

3) Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM (NEGATIVE 

BATTERY TERMINAL IS CONNECTED TO CHASSIS).
3a. Connect positive (+) red clamp to vehicle battery’s positive terminal.
3b. Connect negative (-) black clamp to chassis or a solid, non-moving, metal

vehicle component or body part. Never clamp directly to negative battery
terminal or moving part. If the audible alarm sounds, the polarity is not 
correct. Reverse the connections. 

4) Procedure for jump-starting POSITIVE GROUND SYSTEMS 

NOTE

: In the rare event that the vehicle to be started has a Positive Grounded

System (positive battery terminal is connected to chassis) replace steps 3a and
3b above with steps 4a and 4b, then proceed to steps 5 through 7 below.
4a. Connect negative (-) black clamp to vehicle battery’s negative terminal.
4b. Connect positive (+) red clamp to vehicle chassis or a solid, non-moving,

metal vehicle component or body part. DO NOT CLAMP DIRECTLY TO 
POSITIVE BATTERY TERMINAL OR MOVING PART.

5) Start vehicle (do not turn key for longer than 3-5 seconds).
6) After vehicle starts, remove clamps (disconnect the frame or engine clamp first,

followed by the battery cable) and replace them in the built-in storage location.
Squeeze the handles and slide the clamp into position and release your grip.

CAUTION:

1) If engine fails to start, leave ignition key turned off. Try again later - the engine

may be flooded.

2) Recharge jump-start system after each use.

WARNING:

1) Always disconnect the engine or frame jumper clamp first; followed by the 

battery jumper clamp.

7

FIGURE 2A

AC charger

FIGURE 2B

DC charger

Summary of Contents for VEC012POB

Page 1: ... DC Portable Power Supply 450 Amp Instant Starting Power Portable Cordless Rechargeable IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR PURCHASE CALL TOLL FREE 866 584 5504 IN MOST CASES A SERVICE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE 12V POWER SUPPLY Jump Start System ...

Page 2: ...use short circuits or react with battery acid 10 Always disconnect the negative black jumper cable first followed by the positive red jumper cable except for positive ground systems 11 Never allow red and black clamps to touch each other or another common metal conductor This could cause damage to the unit and or create sparking explosion hazard Always store battery clamps in built in holsters whe...

Page 3: ...e adapter The adapter barrel connector attaches to the recharge port on the top panel of the jump starter A built in 12 volt appliance outlet and the appropriate DC DC charging adapter cord is used to recharge the battery from another 12 volt DC source When pressed the charge status pushbutton will show the battery power level status on the battery status display from low to full The green LED ful...

Page 4: ...battery 4 Vehicles that have on board computerized systems may be damaged if vehicle battery is jump started Before jump starting this type of vehicle read the vehicle owner s manual to confirm that external starting assistance is advised 5 Excessive engine cranking can damage the vehicle s starter motor If the engine fails to start after the recommended number of attempts discontinue jump start p...

Page 5: ... switch to ON if the Reverse Polarity LED is lit or alarm sounds If inadvertent reverse polarity occurs the alarm will sound and the red LED will light Disconnect the black clamp negative clamp first then the red clamp Reconnect the polarity properly and then turn the key To recap CONNECT Red clamp first then black clamp DISCONNECT Black clamp first then red clamp 1 Turn OFF vehicle ignition and a...

Page 6: ...er exceed recommended pressures Bursting articles can cause serious injury Always check pressure with the pressure gauge Never leave compressor unattended while in use Allow unit to cool after 10 minutes of continuous operation 3 After initial 48 hour charge charge this device for at least 14 16 hours or until the green FULL indicator lights Charge at least once a month when not in use 4 When char...

Page 7: ... volt DC AC Charging Adapter 120 volt AC 700mA 12 volt DC Output 6 2 Tire Inflation or Products with a Valve Stem 1 Place connector chuck on valve stem 2 Push connector toward valve stem and close thumb latch 3 Make sure connector is pushed onto valve stem as far as possible before closing thumb latch 4 Check pressure with the pressure gauge 5 When desired pressure is reached turn Off compressor p...

Reviews: