As soon as the tank pressure is built up, the motor switches off 
automatically. 

The motor switches automatically on as soon as the tank pressure 
becomes too low. 

8.4 

Safety valve 

The safety valve has been set for the highest permitted pressure of the pressure vessel. It is 
prohibited to adjust the safety valve or remove its seal 
Actuate the safety valve from time to time to ensure that it works when required. Therefore you 
need to remove the protection cover. 

9  PNEUMATIC CHISEL/HAMMER SET 

9.1 

Appliance 

Ideal for general cutting, chipping and scraping. 

9.2 

Loading and operation (Fig. 6) 

WARNING: Ensure you read, understand and apply safety instructions 
before use. 

1. 

Connect the tool to the air hose. 

2. 

Press the trigger to operate the tool.  

3. 

The flow of air may be regulated by adjusting flow valve at the base of the handle. 

4. 

Ensure the air supply is clean and does not exceed 90psi while operating the tool. Too 
high an air pressure and unclean air will shorten the product life due to excessive wear, 
and may be dangerous causing damage or personal injury. 

If a filter/regulator/lubricator is not installed on the air system, air operated 
tools should be lubricated at least once a day or after 2 hours work with 2 to 
6 drops of oil, depending on the work environment, directly through the 
male fitting in the tool housing. 

10 BLOW GUN 

Use 

Method of use 

Recommended 
Pressure 

Blowing  

Connect  the  compressed  air  supply  to  fitting.  Press  the 
trigger and direct the jet over the surface to be blown.  

Adjust  the  pressure 
according to need 

WARNING! Wear eye protection! Air blast can cause debris and dust to be 
blown back towards you. 

 

 

Summary of Contents for 829580

Page 1: ...vice 5 6 SPECIFIC SAFETY WARNINGS 6 6 1 Do s 6 6 2 Don ts 6 6 3 Things you should know 7 7 ASSEMBLY 7 7 1 Point to know when setting up the compressor 7 7 2 Fitting the wheels 7 7 3 Fitting the suppor...

Page 2: ...RO P a g e 2 www varo com 12 CLEANING AND MAINTENANCE 10 12 1 Cleaning 10 12 2 Maintenance 10 13 TECHNICAL DATA 10 14 NOISE 10 15 STORAGE 10 16 TROUBLE SHOOTING 11 17 WARRANTY 12 18 ENVIRONMENT 12 19...

Page 3: ...e instructions 2 DESCRIPTION FIG 1 2 1 Shroud 2 Pressure vessel 3 Wheel 4 Supporting foot 5 Quick lock coupling 6 Pressure gauge 7 Pressure regulator 8 ON OFF switch 9 Transportation handle 10 Pressur...

Page 4: ...ractions can cause you to lose control 5 2 Electrical safety Always check that the power supply corresponds to the voltage on the rating plate Power tool plugs must match the outlet Never modify the p...

Page 5: ...not force the power tool Use the correct power tool for your application The correct power tool will do the job better and safer at the rate for which it was designed Do not use the power tool if the...

Page 6: ...placed on a stable horizontal surface 6 2 Don ts Never direct the jet of air towards persons animals or your body Always wear safety goggles to protect your eyes against flying objects that may be li...

Page 7: ...r Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust free Do not set up the compressor in damp or wet rooms The compressor may only be used in suitable room...

Page 8: ...the air hose 2 Press the trigger to operate the tool 3 The flow of air may be regulated by adjusting flow valve at the base of the handle 4 Ensure the air supply is clean and does not exceed 90psi wh...

Page 9: ...ep the nailer pointed away from yourself and others and connect to the hose Position the nailer nose against work piece and pull the trigger Disconnect air supply in case a nail or stapler is jammed P...

Page 10: ...ECHNICAL DATA Type POWX1751 Rated power 1 5hp 1100W Current take off 5A Power supply voltage 230 V 50 Hz Air intake 180l min Maximum pressure 8bar 116PSI Weight 22kg Tank capacity 50l Rotation speed 3...

Page 11: ...compressor stops and restarts automatically after a few minutes Tripping of the thermal cutout due to overheating of the motor Clean the air ducts Ventilate the work area After a few attempts to resta...

Page 12: ...etration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the instructions given in...

Page 13: ...us voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2014 30 EU 2006 42 EC 2000 14 EC Annex VI LwA 95dB A 97dB A testing author...

Reviews: