11
Fault Conditions & Advisements
(continued)
The flash patterns for advisements are as follows:
LED Pattern
Advisement
Solid ORANGE
(Battery removed.)
Brief reset period for charger after battery is removed. Allow the LED to go off before
inserting another battery.
Solid ORANGE
(Battery inserted.)
Indicates battery is too cold when initially inserted. If the battery temperature is 0°C
(32° F) or below, charging is delayed for up to two hours. Battery is monitored and charging
resumes once it is above freezing. Monitoring terminates if the battery temperature remains
below freezing for two hours.
Flashes ORANGE
1 Time
Battery temperature remains at 0°C (32° F) or below after two hours of monitoring.
Remove battery from charger and allow it to warm.
Flashes ORANGE
2 Times
Indicates charging complete, but battery is under charged. Battery voltage is below
minimum level required. This warning is provided after the rapid charging stage is
complete.
Summary of Contents for ENDURA EC12M
Page 1: ...Twelve Unit Rapid Charger FOR RECHARGEABLE LMR RADIO BATTERIES User Manual Model EC12M ...
Page 2: ......
Page 19: ......