1 Safety Description
3
In case of fire, please use dry power fire extinguisher. If using liquid fire extinguisher, it may cause
electric shock.
1.1.2 PV String Protection
When install PV string in daytime, it necessary to cover the PV string by light-proof material, or the
PV string will generate high voltage under sunshine. If touching PV string accidently, it may cause
electric shock or human injury!
There exists dangerous voltage between the positive and negative of PV string!
When installing the device, make sure that the connection between inverter and PV string has been
disconnected completely. And set warning mark in the disconnected position to avoid reconnecting.
1.1.3 ESD Protection
To prevent human electrostatic damaging sensitive components (such as circuit board), make sure
that you wear a anti-static wrist strap before touching sensitive components, and the other end is well
grounded.
1.1.4 Grounding Requirements
High leakage risk! The inverter must be grounded before wiring. The grounding terminal must be
connected to ground, or, there will be the risk of electric shock when touching the inverter.
When installing, the inverter must be grounded first. When dismantling, the grounding wire must
be removed at last;