FOLDING STAIRWAY
Caterpillar D11R Dozer
Pg29
PSA-D11R-F/L
210610
10)
Once the ladder has been raised and reached its top proximity switch the hydraulic
motor will run for an additional three seconds to ensure it is fully stowed.
11)
This system also features optional locks which are for any electric or electric over
hydraulic function which may need to be locked out to prevent damage to the
ladder system (i.e.) swing and/or travel on excavators. This can be used with or
without the park brake system. The system has N.O. and N.C. options and can be
used easily integrated into any system to inhibit swing/travel until the ladder is fully
raised.
12)
This system also features an optional door proximity switch; this switch if used, is
designed to prevent the ladder from being raised if the cab door is ajar. It is a N.O.
proximity thus; if this option is not used the bypass plug must be fitted. If the cab
door is accidentally opened whilst the ladder is being raised, it will stop and then
continue once the cab door is closed again.
13)
Motion delay can be inhibited by removing Diode 6 to inhibit the delay in the
upward direction. Diode 7 can be removed to inhibit the delay in the downward
direction.
14)
Mounted in the optional Boarding Lamp Switch Housing is an additional lower
button, this is to enable the operator to operate the down function from an
alternative position, one or more of these stations can be used.
15)
Should the park brake system not be used, a by-pass plug must be fitted otherwise
the alarm in the cab will not operate. In this condition the alarm in the cab will
operate whenever the step is not fully home (up). We recommend during shutdowns
or extended periods of time when the machine is to be worked on with the ladder
down, the system be isolated.
16)
The system must have both the up (top) and down (bottom) Proximity Switches
used.
17)
The timers are all set for different functions and must not be interchanged.
18)
The circuit breakers used are called alternative function circuit breakers which
mean if they "trip out" on over current the supply must be cut and then re-applied to
re-set them - turn the system off and then back on.
19)
The kit is supplied with a 120 amp Circuit Breaker/Bracket Assembly. We
recommend taking the power supply from the isolated side of the battery isolator (If
positive is isolated) or the battery itself. The circuit breaker should be mounted as
close to the battery positive terminal as possible, using the cable lug covers for all
exposed connections and a minimum of 3AWG/3B+S battery cable. Larger cable is
recommended on a long cable run. Suitable cable protection and cable restraints
should be used in accordance with normal good practice.
Access System Electrical Overview (cont.)
Summary of Contents for PSA-D11R-FL
Page 13: ...FOLDING LADDER Caterpillar D11R Dozer Section 5 Assembly Complete Pg13 PSA D11R F L 210610 ...
Page 14: ...FOLDING LADDER Caterpillar D11R Dozer Section 5 1 Ladder Assembly Pg14 PSA D11R F L 210610 ...
Page 19: ...FOLDING LADDER Caterpillar D11R Dozer Section 5 4 Spreader Assembly Pg19 PSA D11R F L 210610 ...